2024
DOI: 10.1002/aoc.7452
|View full text |Cite
|
Sign up to set email alerts
|

A dual‐responsive luminescent sensor for efficient detection of 3‐nitrotyrosine and dipicolinic acid biomarkers based on copper(II) organic framework

Wenqian Li,
Wencui Li,
Xin Liu
et al.

Abstract: The trace detection of biomarkers in real samples has profound a most important significance in the early diagnosis and daily monitoring of diseases. Based on the ligand pre‐design strategy, a novel 3D CuMOF, with the formula of {[Cu4(BTPB)(μ2‐OH)2(H2O)5]·3H2O}n, was fabricated by using the hexacarboxyl ligand of 1,4‐bis(2,4,6‐tricarboxylpyrid‐5‐yl)benzene (H6BTPB) and tetranuclear {Cu4(COO)4(μ2‐OH)2} SBUs. Benefiting from the robust framework and unique luminescence performance, the prepared CuMOF displays gr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(2 citation statements)
references
References 75 publications
0
2
0
Order By: Relevance
“…The Zn-MOF can be used as an effective fluorescence sensor for sensing the biomarker 3-nitrotyrosinea (3-NT) with a K SV value of 6.596 × 10 4 M −1 [ 25 ]. Recently, Fan’s group proposed a Ni(II) metal–organic framework under a mixed-ligand method, and subsequently proved its excellent sensing properties in detecting 3-NT biomarker and HA biomarker in real samples [ 26 ]. As of now, “turn-off” responses (where fluorescence intensity decreases) are frequently used in documented examples to detect any analytes; on the contrary, “turn-on” responses (where fluorescence intensity increases) are uncommon [ 27 ].…”
Section: Introductionmentioning
confidence: 99%
“…The Zn-MOF can be used as an effective fluorescence sensor for sensing the biomarker 3-nitrotyrosinea (3-NT) with a K SV value of 6.596 × 10 4 M −1 [ 25 ]. Recently, Fan’s group proposed a Ni(II) metal–organic framework under a mixed-ligand method, and subsequently proved its excellent sensing properties in detecting 3-NT biomarker and HA biomarker in real samples [ 26 ]. As of now, “turn-off” responses (where fluorescence intensity decreases) are frequently used in documented examples to detect any analytes; on the contrary, “turn-on” responses (where fluorescence intensity increases) are uncommon [ 27 ].…”
Section: Introductionmentioning
confidence: 99%
“…27,28 MOFs have been considered good platforms for constructing luminescent sensors for detecting various pollutants over the past few decades. 29–34 However, the detection of acetone and TEA in water by luminescent MOF sensors is still relatively limited, 22,35 to the best of our knowledge.…”
Section: Introductionmentioning
confidence: 99%