2009
DOI: 10.1016/j.ajic.2009.03.014
|View full text |Cite
|
Sign up to set email alerts
|

A fall in bloodstream infections followed a change to 2% chlorhexidine in 70% isopropanol for catheter connection antisepsis: A pediatric single center before/after study on a hemopoietic stem cell transplant ward

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
35
1
3

Year Published

2013
2013
2024
2024

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 66 publications
(39 citation statements)
references
References 16 publications
0
35
1
3
Order By: Relevance
“…Alcoholic chlorhexidine performed consistently well or better than other disinfection agents in multiple studies [21,24,131,168,172,179,182]. In the research by Hong et al, a 5 second scrub with alcoholic chlorhexidine fully disinfected NC surfaces treated with Pseudomonas Aeruginosa [179].…”
Section: Disinfection Practicesmentioning
confidence: 99%
See 2 more Smart Citations
“…Alcoholic chlorhexidine performed consistently well or better than other disinfection agents in multiple studies [21,24,131,168,172,179,182]. In the research by Hong et al, a 5 second scrub with alcoholic chlorhexidine fully disinfected NC surfaces treated with Pseudomonas Aeruginosa [179].…”
Section: Disinfection Practicesmentioning
confidence: 99%
“…Recommendations from both the Centers for Disease Control and the Infusion Nurses Society state clinician should minimize contamination risk by disinfection the access ports of the add-on device using friction with an appropriate disinfectant (70% alcohol, chlorhexidine, povidone iodine, and iodophors) prior to any access [8,11,24,167,168]. The 70% isopropyl alcohol wipe is most commonly used to disinfect the access surface of NC and has been proven effective or ineffective at disinfection times from 5 seconds to 60 seconds [14, 19, 24-27, 131, 151, 169-177].…”
Section: Disinfection Practicesmentioning
confidence: 99%
See 1 more Smart Citation
“…In recent years, injection through stopcock injection ports has been identified as a potential portal of entry for microorganisms. In general closed catheter systems, used with the appropriate disinfection, have been associated with fewer catheter-related blood stream infections (Casey et al, 2007;O'Grady et al, 2011;Niel-Weise et al, 2006;Soothill et al, 2009). However, Esteve et al (2007) claim that closed catheter systems do not reduce infection rates.…”
Section: Introductionmentioning
confidence: 99%
“…It has been shown that external disinfection of the devices with chlorhexidine/alcohol, rather than alcohol alone, can reduce IVC colonization. 47,54 In addition, the time spent on applying the disinfectant is important. Results from one study suggest that wiping the connector with 70% isopropyl alcohol for 3-5 seconds did not adequately disinfect the septal surface.…”
mentioning