2015
DOI: 10.1016/j.nima.2015.04.058
|View full text |Cite
|
Sign up to set email alerts
|

A first comparison of the responses of a 4He-based fast-neutron detector and a NE-213 liquid-scintillator reference detector

Abstract: He NE-213 Scintillation Gamma-rays Fast neutrons Pulse-shape discrimination a b s t r a c t A first comparison has been made between the pulse-shape discrimination characteristics of a novel 4 He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neutrons and gamma-rays wer… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 17 publications
(15 citation statements)
references
References 21 publications
0
12
0
Order By: Relevance
“…The ∼1.8 ns FWHM of the gamma-flash distribution is consistent with the observed timing jitter on our PMT signals and the slight tail in the distribution is possibly due to time walk in the electronics. Note that 4 He scintillator is highly insensitive to gamma-rays [14,18] and any electrons produced via Compton scattering or pair production will result in only a very small scintillation signal. These events will be entirely suppressed by the relatively high software Also shown are three representations of the neutron-kinetic energy distribution constructed using the information presented by Thomas in Ref.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The ∼1.8 ns FWHM of the gamma-flash distribution is consistent with the observed timing jitter on our PMT signals and the slight tail in the distribution is possibly due to time walk in the electronics. Note that 4 He scintillator is highly insensitive to gamma-rays [14,18] and any electrons produced via Compton scattering or pair production will result in only a very small scintillation signal. These events will be entirely suppressed by the relatively high software Also shown are three representations of the neutron-kinetic energy distribution constructed using the information presented by Thomas in Ref.…”
Section: Resultsmentioning
confidence: 99%
“…NE-213 is an organic liquid scintillator that has been employed for decades as a fast-neutron detector. The NE-213 liquid-scintillator detector used here has been reported upon earlier [1,18,19]. It consisted of a 62 mm long × 94 mm cylindrical aluminum "cup" fitted with a borosilicate glass optical window [20].…”
Section: Ne-213 Fast-neutron and Gamma-ray Liquid-scintillator Detectormentioning
confidence: 99%
“…More importantly, the detector is naturally less sensitive to gamma-rays because the recoiling electron will likely travel far enough to deposit some of its energy into the detector wall instead of the scintillating gas [1]. Thus, the main discrimination strategy in the modern iteration of the detector is simply to compare the size of the pulse and discard events below a threshold as electron recoil backgrounds [9,10]. For neutron recoils, on the other hand, the detector has been used to extract spectral information about neutron sources [5,11,12].…”
Section: Introductionmentioning
confidence: 99%
“…Sensitivity to fast neutrons described above also contributes to background. Due to the pulsed nature of a spallation source, fast neutrons due 1The same mechanism, energy loss by inelastic scattering, is used in 4 He detectors for fast neutrons [30]. to the spallation process, arrive in a peak at a fixed time with respect to the elastic peak and other features.…”
Section: Introductionmentioning
confidence: 99%