2006
DOI: 10.1016/j.nima.2006.08.115
|View full text |Cite
|
Sign up to set email alerts
|

A fundamental method to determine the signal-to-noise ratio (SNR) and detective quantum efficiency (DQE) for a photon counting pixel detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

4
72
0

Year Published

2008
2008
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 47 publications
(76 citation statements)
references
References 7 publications
4
72
0
Order By: Relevance
“…Several detector developers have worked towards the introduction of charge-sharing effects in image quality modelling of PC-HPDs [4][5][6][7][8][9][10][11][12][13][14][15][16]. By simulating charge collection processes in highly segmented PC-HPDs, Tlustos demonstrated how count loss and multiple counting were both decreasing the zero-frequency DQE of PC-HPDs and how multiple counts resulting from charge-sharing effects were acting as a low pass (or anti-aliasing) filter on the image by widening the presampling MTF of the detector [4].…”
Section: Jinst 7 P11028mentioning
confidence: 99%
See 1 more Smart Citation
“…Several detector developers have worked towards the introduction of charge-sharing effects in image quality modelling of PC-HPDs [4][5][6][7][8][9][10][11][12][13][14][15][16]. By simulating charge collection processes in highly segmented PC-HPDs, Tlustos demonstrated how count loss and multiple counting were both decreasing the zero-frequency DQE of PC-HPDs and how multiple counts resulting from charge-sharing effects were acting as a low pass (or anti-aliasing) filter on the image by widening the presampling MTF of the detector [4].…”
Section: Jinst 7 P11028mentioning
confidence: 99%
“…In their model they approximated the X-ray induced charge cloud by a uniform charge distribution. Another major step consisted in the introduction by Michel et al of a DQE model of PC-HPDs based on the mean and variance of the count multiplicity [5,7]. However this model is restricted to the zero-frequency DQE.…”
Section: Jinst 7 P11028mentioning
confidence: 99%
“…In addition, angiography requires high spatial resolution but the use of small detector elements will result in reabsorption of characteristic and Compton-scatter x rays and therefore charge sharing in near-by elements. This may result in increased image noise [26][27][28][29][30][31][32][33] although fast coincidence detection algorithms, such as that implemented in the Medipix-3 prototype detector, 29 may prevent these effects.…”
Section: Introductionmentioning
confidence: 99%
“…Secondly, the charge signal transport is affected by charge sharing. The moving charge cloud also induces electrical pulses on neighboring pixels, [17], again mostly at the funnelshaped bottom part of the pixel field configuration.…”
Section: Methodsmentioning
confidence: 99%