2020
DOI: 10.2116/analsci.20p101
|View full text |Cite
|
Sign up to set email alerts
|

A Green Chemosensor for Colorimetric Determination of Phosphate Ion in Soil, Bone, and Water Samples Using Curcumin Nanoparticles

Abstract: This article presents a sensitive and straightforward colorimetric chemosensor for the determination of phosphate ion utilizing curcumin nanoparticles (CUNPs) as the sensing system. The color of as-prepared CUNPs can be changed from yellow to orange upon adding iron(III) ions due to the formation of a complex with CUNPs. However, in the presence of phosphate ions, iron(III) ions prefer to bind to phosphate ions and, subsequently the color of CUNPs is selectively recovered because of releasing the iron(III) ion… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0
2

Year Published

2021
2021
2025
2025

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 29 publications
0
2
0
2
Order By: Relevance
“…The limit of detection (LOD) was calculated to be 5.4 µg/L according to three times the signal-to-noise (S/N = 3) ratio. The analytic performance of the proposed method with other nanomaterials-related methods for Pi detection was compared [10,[30][31][32][33][34][35] (Table S3). It exhibits that the LOD of the proposed method is the lowest among the colorimetric method [33][34][35], and even lower than some fluorescence methods [30,31] and voltammetry [10].…”
Section: Colorimetric Assay For Detection Of Pimentioning
confidence: 99%
See 1 more Smart Citation
“…The limit of detection (LOD) was calculated to be 5.4 µg/L according to three times the signal-to-noise (S/N = 3) ratio. The analytic performance of the proposed method with other nanomaterials-related methods for Pi detection was compared [10,[30][31][32][33][34][35] (Table S3). It exhibits that the LOD of the proposed method is the lowest among the colorimetric method [33][34][35], and even lower than some fluorescence methods [30,31] and voltammetry [10].…”
Section: Colorimetric Assay For Detection Of Pimentioning
confidence: 99%
“…The analytic performance of the proposed method with other nanomaterials-related methods for Pi detection was compared [10,[30][31][32][33][34][35] (Table S3). It exhibits that the LOD of the proposed method is the lowest among the colorimetric method [33][34][35], and even lower than some fluorescence methods [30,31] and voltammetry [10]. The low LOD is probably due to the special structure and composition of Co-MOF.…”
Section: Colorimetric Assay For Detection Of Pimentioning
confidence: 99%
“…Erreakzioa bi urratsetan gertatzen da: lehenengoan (3. erreakzioa) «Keggin ioi» bat osatzen da, eta bigarrenean (4. erreakzioa), horren erredukzioa ematen da kolore urdin sakona duen produktua sortuz [33]. Konplexuaren kolorea UV-Vis espektrofotometria bidez neur daiteke, baita kolorimetrian oinarritutako beste metodo batzuen bidez ere [34,35]. Lagin mota hauen pH-a determinatzea ere oso garrantzitsua da.…”
Section: Dia Eta Medikuntza: Malko Artifizialen Analisiaunclassified
“…Erreakzioa bi urratsetan gertatzen da: lehenengoan (1) "Keggin ioi" bat osatzen da, eta bigarrenean (2), horren err edukzioa ematen da kolore urdina duen produktua sortuz . Konplexuaren kolorea UV-Vis espektrofotometria bidez neur daiteke, baita kolorimetrian oinarritutako beste metodo batzuen bidez ere (Knyazev et al, 2007;Pourreza et al, 2020).…”
Section: Sarrera Eta Motibazioaunclassified