A high resolution animal PET scanner using compact PS-PMT detectors

Abstract: A new high resolution PET scanner dedicated to animal studies has been designed, built and tested. The system utilizes 240 block detectors, each of which consists of a new compact position-sensitive photomultiplier tube (PS-PMT) and an 8 x 4 BGO array. A total number of 7,680 crystals (480 per ring) are positioned to form a 508 mm diameter of 16 detector rings with 7.2 mm pitch and 114 mm axial field of view (FOV).The system is designed to perform activation studies using a monkey in a sitting position. The da… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
61
0
1

Year Published

2000
2000
2014
2014

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 222 publications
(62 citation statements)
references
References 10 publications
0
61
0
1
Order By: Relevance
“…7 Furthermore, by in vivo assay in rat using small animal PET, although dose escalation study was impossible because of the lethal effects of rotenone on cardiac function, the significant reduction in uptake into the brain as well as into the heart was observed even at a relatively low dose of 0.1 mg/kg per hour. 7,8 18 F-fluoro-2-deoxy-D-glucose is useful with easier operation compared with rCBF and rCMRO 2 measurements with three consecutive measurements using very short half-life 15 O-gases. However, as shown in the present study, higher accumulation of 18 F-FDG occurred in both ROI PBR and ROI Infarct than on the Figure 2.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…7 Furthermore, by in vivo assay in rat using small animal PET, although dose escalation study was impossible because of the lethal effects of rotenone on cardiac function, the significant reduction in uptake into the brain as well as into the heart was observed even at a relatively low dose of 0.1 mg/kg per hour. 7,8 18 F-fluoro-2-deoxy-D-glucose is useful with easier operation compared with rCBF and rCMRO 2 measurements with three consecutive measurements using very short half-life 15 O-gases. However, as shown in the present study, higher accumulation of 18 F-FDG occurred in both ROI PBR and ROI Infarct than on the Figure 2.…”
Section: Discussionmentioning
confidence: 99%
“…Positron-emitting carbon-11 ( 11 C), oxygen-15 ( 15 O), and fluorine-18 ( 18 F) were produced by 14 N(p, a) 11 C, 14 N(d, n) 15 O, and 18 O(p, n) 18 F nuclear reactions, respectively, using a cyclotron (HM-18; Sumitomo Heavy Industry, Tokyo, Japan) at Hamamatsu Photonics PET Center. Labeled compounds were synthesized using a modified CUPID system (Sumitomo Heavy Industries, Ltd., Tokyo, Japan).…”
Section: Positron Emission Tomography Ligand Synthesesmentioning
confidence: 99%
See 3 more Smart Citations