2021
DOI: 10.1016/j.foodchem.2021.130021
|View full text |Cite
|
Sign up to set email alerts
|

A high sensitive platinum-modified colloidal gold immunoassay for tenuazonic acid detection based on monoclonal IgG

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 18 publications
(27 citation statements)
references
References 37 publications
0
27
0
Order By: Relevance
“…The successfully prepared AuNPs, with an average diameter of 15 nm, were used as the signal reporters of the AuNPs-based strip, for rapidly detecting αB-CTX. It is well known that the size of the AuNPs is an important factor to improve the sensitivity of detection [ 23 ]. Nanoflower gold particles (AuNFs), with a multi-branched surface and large size, have been widely used as signal reporters to enhance the sensitivity of detection [ 17 ].…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The successfully prepared AuNPs, with an average diameter of 15 nm, were used as the signal reporters of the AuNPs-based strip, for rapidly detecting αB-CTX. It is well known that the size of the AuNPs is an important factor to improve the sensitivity of detection [ 23 ]. Nanoflower gold particles (AuNFs), with a multi-branched surface and large size, have been widely used as signal reporters to enhance the sensitivity of detection [ 17 ].…”
Section: Resultsmentioning
confidence: 99%
“…The AuNFs were prepared by using the seeding growth method, and the pH of the solution significantly affected the color of the solution and the shape of the AuNFs. A pH of 7.0 in the reaction solution was suitable for the synthesis of AuNFs, according to previous reports [ 17 , 23 ]. As shown in Figure 5 A, the color of the nanoflower solution was deep blue, with good transparency and stability, and the prepared AuNFs showed a complex three-dimensional and flower-like shape under TEM observation.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Moreover, complicated and tedious operation steps, high requirement of samples and detection practicability seriously limits their application in the detection of αB-CTX in real samples [ 19 ]. In contrast, immunoassays with high sensitivity, accuracy and adaptability have been widely used to detect the targets (toxins, pathogenic molecules and heavy metals) in different samples [ 20 , 21 , 22 ]. In the previous study, we developed ELISA and colloidal test strips based on monoclonal antibodies (mAb) against ω-CTX to detect ω-CTX MVIIA residue in Conus samples [ 5 ].…”
Section: Introductionmentioning
confidence: 99%