A high-sensitivity compact gas concentration sensor using ultraviolet light absorption with a heating function for a high-precision trimethyl aluminum gas supply system

Abstract: This work presents a high-sensitivity, real-time, compact gas concentration sensor using a time-sharing dual-wavelength UV light absorption method developed for a high-precision trimethyl aluminum (TMA) gas supply system. We analyzed the characteristics of TMA, examined a method to increase sensitivity by controlling the gas transition, and fabricated a highly reliable heatable gas cell. The detection circuit demonstrated that TMA can be measured stably using a charge amplifier method that can detect various m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 28 publications
0
3
0
Order By: Relevance
“…Typical wavelength of various substances used for absorption analysis are shown in Fig. 3 [8][9][10][11][12][13][14] . Wavelengths used for analysis after appropriate chemical pre-treatment are also included in Finally, it should have high framerate and global shutter (GS) operation.…”
Section: Technical Requirementsmentioning
confidence: 99%
“…Typical wavelength of various substances used for absorption analysis are shown in Fig. 3 [8][9][10][11][12][13][14] . Wavelengths used for analysis after appropriate chemical pre-treatment are also included in Finally, it should have high framerate and global shutter (GS) operation.…”
Section: Technical Requirementsmentioning
confidence: 99%
“…Therefore, it is impossible to evaluate gas replacement characteristics in spite of its importance for developing ALD technology. So far, we developed a highly sensitive, real-time, and compact gas concentration sensor using the ultraviolet (UV) absorption method (5,6). This sensor can estimate concentrations of gases having absorption in UV range using Beer-Lambert law.…”
Section: Introductionmentioning
confidence: 99%
“…Several concentration measurement methods using light absorption have been utilized in high-performance liquid chromatography with linear array sensor [3], [4], gas concentration sensor with a single photodiode (PD) [5], and so on. Equation (1) where N sig is the number of signal electrons and n sys is the number of input-referred system noise electrons.…”
mentioning