2017
DOI: 10.1007/s00216-017-0591-4
|View full text |Cite
|
Sign up to set email alerts
|

A high-throughput QCM chip configuration for the study of living cells and cell-drug interactions

Abstract: In this study, we present a novel design of interference-free, negligible installation-induced stress, suitable for the fabrication of high-throughput quartz crystal microbalance (HQCM) chips. This novel HQCM chip configuration was fabricated using eight independent yet same-batch quartz crystal resonators within a common glass substrate with eight through-holes of diameter slightly larger than that of the quartz resonator. Each quartz resonator's rim was adhered to the inner part of the through-hole via silic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 15 publications
(15 citation statements)
references
References 33 publications
0
15
0
Order By: Relevance
“…The immunoassay format, based on antibody–antigen (Ab–Ag) interactions, remains a robust, ubiquitous analytical tool [ 21 ]. Indeed, a number of QCM immunosensors [ 22 ] have been reported for the determination of different analytes, such as glucose [ 4 ], microbes [ 23 , 24 , 25 , 26 , 27 ], nucleic acids [ 28 , 29 ], environmental pollutants [ 30 ], cells [ 31 ], and food pathogens [ 32 ], for drug discovery applications, and for diagnostics and biomedical applications [ 33 ].…”
Section: Introductionmentioning
confidence: 99%
“…The immunoassay format, based on antibody–antigen (Ab–Ag) interactions, remains a robust, ubiquitous analytical tool [ 21 ]. Indeed, a number of QCM immunosensors [ 22 ] have been reported for the determination of different analytes, such as glucose [ 4 ], microbes [ 23 , 24 , 25 , 26 , 27 ], nucleic acids [ 28 , 29 ], environmental pollutants [ 30 ], cells [ 31 ], and food pathogens [ 32 ], for drug discovery applications, and for diagnostics and biomedical applications [ 33 ].…”
Section: Introductionmentioning
confidence: 99%
“…Such configuration, as a consequence, may originate a softer layer with an increase of dissipation value. The softening effect of Y27632 has been reported for different cell lines as H9C2 cardiomyoblasts investigated by high-throughput QCM chips [45] and MDA-MB-231 metastatic breast cancer cells using Atomic Force Microscopy. [46] The dissipation increase is also consistent with a previous confocal microscopy observation for MCF7 transfected cells [47] that described the ability of Y27632 to sever actin filaments in addition to softening it, and by our CLSM experimental findings that demonstrated the disappearance of elastic and compact stress fibers ( Figure 4B).…”
Section: Discussionmentioning
confidence: 99%
“…High-throughput QCM (HQCM) chip for the study of cell-drug interactions Configuration of interference-free, negligible installation-induced stress Fabricated using independent yet same-batch quartz crystal resonators within a common glass substrate through the rigid (quartz)-soft (silicone)-rigid (glass) structure [17] Cell−material interactions Tuning the surface free energy of materials…”
Section: Application Examples Technical Feature Technical Characteristicsmentioning
confidence: 99%