2017
DOI: 10.1016/j.aca.2016.11.006
|View full text |Cite
|
Sign up to set email alerts
|

A high-throughput screening method of bisphenols, bisphenols digycidyl ethers and their derivatives in dairy products by ultra-high performance liquid chromatography-tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
23
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 50 publications
(24 citation statements)
references
References 29 publications
1
23
0
Order By: Relevance
“…The biggest difference can be observed for the MRM transition of BADGE·H 2 O·HCl, where the response obtained using MeOH is about 20 times higher than that obtained using ACN. This phenomenon has already been reported for this family of compounds [14, 16]. Moreover, the use of MeOH resulted in better peak shapes than those obtained using ACN.…”
Section: Resultssupporting
confidence: 75%
See 1 more Smart Citation
“…The biggest difference can be observed for the MRM transition of BADGE·H 2 O·HCl, where the response obtained using MeOH is about 20 times higher than that obtained using ACN. This phenomenon has already been reported for this family of compounds [14, 16]. Moreover, the use of MeOH resulted in better peak shapes than those obtained using ACN.…”
Section: Resultssupporting
confidence: 75%
“…Hydrolyzed derivatives, such as BADGE·2H 2 O, BADGE·H 2 O, BFDGE·2H 2 O, and BFDGE·H 2 O, can be created during storage when food coatings come into contact with aqueous and acidic foodstuffs. Chlorinated derivatives, on the other hand, may be generated during the thermal coating treatment [14, 16]. In Table 1, key information about the BADGE and BFDGE derivatives is summarized.…”
Section: Introductionmentioning
confidence: 99%
“…RSM has been used to evaluate the effects of multiple factors and levels on response variables [37][38][39][40]. The CCD of RSM was used to design and optimize some extraction and purification methods of macrolides.…”
Section: Optimization Of Clean-up By Response Surface Methodsmentioning
confidence: 99%
“…Although these methods play important roles in the detection of β-blockers, they also have some drawbacks. For example, the quantification of the ELISA method is not accurate and the operation is troublesome, and GC-MS involves derivative steps before chromatographic separation, which are time-consuming and which increase the possibility of contamination [18]. And the LC-UV method is limited by poor sensitivity, so it cannot meet the requirements for ultra-trace analyses.…”
Section: Introductionmentioning
confidence: 99%