2017
DOI: 10.1016/j.electacta.2017.02.120
|View full text |Cite
|
Sign up to set email alerts
|

A label free immunosensor for ultrasensitive detection of 17β-Estradiol in water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 31 publications
(13 citation statements)
references
References 26 publications
0
13
0
Order By: Relevance
“…When NPs were spiked in seawater samples, the obtained limit of detection was 23 μM, with an average recovery between 97.8 and 104.6%. Another example is the detection of 17-estradiol 77 in water samples using immunosensors with a good LOD of 0.0036 nM and a short analysis time of 10 minutes. Self-assembled monolayers of 11-mercaptoundecanoic acid were used to create such immunosensors by coupling the electrode with an anti-17-Estradiol antiserum primary monoclonal antibody specific to the antigen (17-estradiol) (MUA).…”
Section: Methods For Detection Of Emerging Contaminantsmentioning
confidence: 99%
“…When NPs were spiked in seawater samples, the obtained limit of detection was 23 μM, with an average recovery between 97.8 and 104.6%. Another example is the detection of 17-estradiol 77 in water samples using immunosensors with a good LOD of 0.0036 nM and a short analysis time of 10 minutes. Self-assembled monolayers of 11-mercaptoundecanoic acid were used to create such immunosensors by coupling the electrode with an anti-17-Estradiol antiserum primary monoclonal antibody specific to the antigen (17-estradiol) (MUA).…”
Section: Methods For Detection Of Emerging Contaminantsmentioning
confidence: 99%
“…Testing for contaminants in water or dairy products such as milk or infant formula proves less restrictive. [256][257][258][259] An obstacle for POC electrochemical devices is the counter electrode (CE) and reference electrode (RE). Maintaining the RE and designing a suitable electrochemical cell can interfere with the portable use of devices.…”
Section: Emerging Technologymentioning
confidence: 99%
“…The bonds between antibodies and antigens are relatively weak and can be dissociated by changing the properties of the environments, i.e., pH and ionic strength. Singh et al developed a simple label-free immunosensor for 17β-estradiol [ 61 ]. Silver wire electrodes were modified with an 11-mercaptoundecanoic acid self-assembled monolayer (SAM) and the 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide (EDC)-N-hydroxy succinimide (NHS) chemistry was used to covalently bind the 17β-estradiol monoclonal antibodies.…”
Section: Eis Biosensors For the Detection Of Edsmentioning
confidence: 99%