2015
DOI: 10.1039/c4em00491d
|View full text |Cite
|
Sign up to set email alerts
|

A laboratory study of the performance of the handheld diffusion size classifier (DiSCmini) for various aerosols in the 15–400 nm range

Abstract: In addition to chemical composition, particle concentration and size are among the main parameters used to characterize exposure to airborne ultrafine or nanoparticles. To assess occupational inhalation exposure, real-time instruments are recommended in recent strategies published. Among portable devices for personal exposure assessment in the workplace, DiSCmini (Matter Aerosol AG, Switzerland) has been identified as a potential candidate with its capacity to measure the airborne nanoparticle concentration an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
20
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(21 citation statements)
references
References 59 publications
1
20
0
Order By: Relevance
“…The charging efficiency of unipolar diffusion chargers has been reported to be proportional to the particle diameter to a power of e.g. 1.034 (Bau, Jacoby, & Witschger, 2012), 1.099 (Bau, Zimmermann, Payet, & Witschger, 2015), 1.11 (Fierz, Burtscher, Steigmeier, & Kasper, 2007), 1.125 (Fierz, Houle, Steigmeier, & Burtscher, 2011) and 1.13 (Jung & Kittelson, 2005;Asbach et al, 2011). The size dependence ( $d p 1.13 ) of the charging efficiency is also shown in Fig.…”
Section: Introductionmentioning
confidence: 82%
See 1 more Smart Citation
“…The charging efficiency of unipolar diffusion chargers has been reported to be proportional to the particle diameter to a power of e.g. 1.034 (Bau, Jacoby, & Witschger, 2012), 1.099 (Bau, Zimmermann, Payet, & Witschger, 2015), 1.11 (Fierz, Burtscher, Steigmeier, & Kasper, 2007), 1.125 (Fierz, Houle, Steigmeier, & Burtscher, 2011) and 1.13 (Jung & Kittelson, 2005;Asbach et al, 2011). The size dependence ( $d p 1.13 ) of the charging efficiency is also shown in Fig.…”
Section: Introductionmentioning
confidence: 82%
“…In the past Bau et al (2015) conducted a very thorough study on the performance of the DiSCmini. They used a variety of monodisperse and polydisperse particles with sizes between 15 and 400 nm with various concentration levels and different morphologies.…”
Section: Introductionmentioning
confidence: 99%
“…It is used to measure the number of particles with diameters ranging between 10 and 500 nm, with a time resolution of 1 s (Supplementary Material, Table S1) and an experimentally tested response time of 7.3 s [14]. The DISCmini can measure a concentration range from about 10 3 to over 10 6 p/cm3, based on the electrical charging of the aerosols.…”
Section: Unmanned Airborne Plume Assessing Systemmentioning
confidence: 99%
“…To avoid artifacts due to coarse particles, the DiSCmini is equipped with an inlet separator with a cutoff diameter of 700 nm. This device has previously been studied in laboratory conditions [30][31][32][33] as well as in field conditions [34][35][36]. In this study, ten specimens of DiSCmini were challenged by the different test aerosols.…”
Section: Diffusion Chargersmentioning
confidence: 99%