2006
DOI: 10.1142/s0217979206040830
|View full text |Cite
|
Sign up to set email alerts
|

A Long Pathlength Spectrophotometric Tegafur Detector Using a Liquid-Core Waveguide

Abstract: A Liquid-Core Waveguide (LCW) detection system for high sensitive determination of tegaful (FT) was developed. In this system the LCW cell was connected to the end of a hollow cathode lump and the other end to a UV spectrometer. A sample solution containing FT was pumped to the LCW cell through a T-shaped connector. A UV absorption of analyte was detected by the UV spectrometer. The configuration of connectors of LCW cell to the light source and the UV detector was designed. Stable and high responses of FT wer… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
1

Year Published

2009
2009
2010
2010

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 5 publications
0
2
0
1
Order By: Relevance
“…; Biogeneral Co. Ltd., San Diego, CA, USA) was connected at the end of a blue diode, and the another end to a compact UV-visible spectrometer (USB 2000-UV-VIS, Ocean Optics Inc., FL, USA) by T-shape connectors. 11 The blue LED component was custom-fabricated by Sato Denki (Tokushima, Japan). The total weight of the system, which consisted of a syringe pump, the LED, the LCW (100 cm), and a compact UV-visible spectrometer, was within 1.5 kg.…”
Section: Rapid Communicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…; Biogeneral Co. Ltd., San Diego, CA, USA) was connected at the end of a blue diode, and the another end to a compact UV-visible spectrometer (USB 2000-UV-VIS, Ocean Optics Inc., FL, USA) by T-shape connectors. 11 The blue LED component was custom-fabricated by Sato Denki (Tokushima, Japan). The total weight of the system, which consisted of a syringe pump, the LED, the LCW (100 cm), and a compact UV-visible spectrometer, was within 1.5 kg.…”
Section: Rapid Communicationsmentioning
confidence: 99%
“…A Teflon AF 2400 has a low refractive index (RI = 1.29), which is lower than that of water (RI = 1.33). [8][9][10][11][12] The light introduced into the liquid core of aqueous samples undergoes total internal reflection at the wall of the Teflon tube. Some analytical applications using both LED and LCW have been reported, 13,14 however, there have not been total systems focused on USB-driven LED and LCW.…”
mentioning
confidence: 99%
“…[1][2][3][4] Estes trabalhos pioneiros da aplicação de um LCW em espectrofotometria, como os de Byrne et aℓ., 1,2 utilizam um aparato óptico próprio, com sistemas de lentes e fibras ópticas convencionais, bem como fontes e detectores específicos e exclusivos para o sistema espectrofotomé-trico, o que torna o sistema relativamente oneroso e dedicado. Aqui propomos a montagem de um dispositivo que permite acoplar uma cela capilar LCW a um espectrofotômetro convencional, de maneira simples e de fácil execução.…”
Section: Espectrofotometria Em Guia De Ondas De Núcleo Líquidounclassified