2022
DOI: 10.1049/hve2.12284
|View full text |Cite
|
Sign up to set email alerts
|

A low‐cost and high‐performance self‐trigger method for high‐voltage transient measurement

Abstract: Stable triggering of acquisition devices is critical to accurately measure electromagnetic transients, especially for very fast transient overvoltages (VFTOs). A highly stable and lowcos t self-trigger method for transient measurement is proposed. An integrated low-voltage arm module was developed to synchronously realise the triggering and VFTO measurement. The trigger branch was developed using a high-pass filter. This component obtained the high-frequency component of the VFTO to trigger the oscilloscope. T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 30 publications
0
5
0
Order By: Relevance
“…Later, Pinnegar et al [39] introduced the adjustment factor δ into the Gaussian window function. Rewrite formula ( 6) to (7).…”
Section: Vmd and Gstmentioning
confidence: 99%
See 1 more Smart Citation
“…Later, Pinnegar et al [39] introduced the adjustment factor δ into the Gaussian window function. Rewrite formula ( 6) to (7).…”
Section: Vmd and Gstmentioning
confidence: 99%
“…Therefore, scholars have extensively studied and hope to use complexity to uniformly characterise the severity of the electromagnetic environment. Evaluating the complexity of electromagnetic interference environments has become an urgent issue in current research [7].…”
Section: Introductionmentioning
confidence: 99%
“…During the plasma discharge process, changes in the background temperature may affect many physical properties of the plasma reactors. [29][30][31][32][33][34][35][36][37][38] To determine its contribution to the physical properties, the effect of temperature on the Lissajous graph was investigated in CO 2 /H 2 mixture. Typical Lissajous graphs under different temperatures at U peak = 6 kV and P dis = 10 W are shown in Figure 2.…”
Section: Dbd Discharge Characteristicsmentioning
confidence: 99%
“…Using electric field sensors for voltage measurement is another solution that has been the subject of research and further improvement [22][23][24][25][26][27][28][29][30][31][32][33]. In [25][26][27][28], the authors propose voltage calculation through inversion or integration of the measured electric field.…”
Section: Introductionmentioning
confidence: 99%