Background
Long-term success of implant restoration depends on many factors one of them is the sufficient implant stability which is lowered in compromised bone density sites such as the maxilla as it is categorized as type III & IV bone, so searching for a new innovation and updates in implant material and features is very mandatory. So, the aim of this study was to compare between two implant materials (roxolid and traditional titanium) on the primary and secondary stability of implant retained maxillary overdenture.
Methods
Eighteen completely edentulous patients were selected. All patients received maxillary implant-retained overdentures and lower complete dentures; patients were divided equally into two groups according to the type of implant materials. Group A received a total number of 36 implants made of roxolid material and Group B received a total number of 36 implants made of traditional titanium alloys. Implant stability was assessed using ostell device, the primary implant stability was measured at the day of implant installation however, secondary implant stability was measured after six weeks of implant placement. Paired t-test was used to compare between primary and secondary stability in the same group and an independent t-test was used to compare between the two groups with a significant level < 0.05.
Results
Independent t-test revealed a significant difference between the two groups with p -value = 0.0141 regarding primary stability and p-value < 0.001 regarding secondary stability, as roxolid implant group was statistically higher stability than titanium group in both. Paired t- test showed a statistically significant difference in roxolid implant group with p-value = 0.0122 however, there was non-statistically significant difference in titanium group with p-value = 0.636. Mann Whitney test showed a significant difference between the two groups regarding amount of change in stability with p value = 0.191. roxolid implant group showed a higher amount of change in stability than the titanium implant group.
Conclusion
Within the limitation of this study, it could be concluded that: Roxolid implants showed better primary and secondary stability than conventional titanium one in implant retained maxillary overdenture.
Trial registration:
NCT06334770 at 27-3-2024.