2020
DOI: 10.1364/oe.401626
|View full text |Cite
|
Sign up to set email alerts
|

A method for spectral irradiance measurement based on a large area WC-C fixed point blackbody

Abstract: We have proposed a novel method for the spectral irradiance measurement of the standard lamp. The measurement has been realized by using national primary scale based on a large area WC-C fixed point blackbody for the first time. The wavelength range is from 450 nm to 1000 nm. The spectral irradiance of the standard lamp has been measured based on the traditional variable temperature blackbody and large area WC-C fixed point blackbody. The results of the two methods agree within the uncertainties. Compared with… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 20 publications
0
3
0
Order By: Relevance
“…When the second melting plateau appeared, the optical platform was moved quickly to the position of the spectral comparator to measure the signal of the HTFP at several wavelengths. When the measurement was completed, the optical platform was quickly moved back to the position of the pyrometer to monitor the end of the melting curve [20,22]. Because of limited number of spectral point could be measure by a comparator during one melting plateau, a few melt/freeze cycles were done to cover the whole spectral range from 250 nm to 2500 nm.…”
Section: Measurement Proceduresmentioning
confidence: 99%
See 2 more Smart Citations
“…When the second melting plateau appeared, the optical platform was moved quickly to the position of the spectral comparator to measure the signal of the HTFP at several wavelengths. When the measurement was completed, the optical platform was quickly moved back to the position of the pyrometer to monitor the end of the melting curve [20,22]. Because of limited number of spectral point could be measure by a comparator during one melting plateau, a few melt/freeze cycles were done to cover the whole spectral range from 250 nm to 2500 nm.…”
Section: Measurement Proceduresmentioning
confidence: 99%
“…In order to meet the increasing needs for high accuracy calibration of spectral irradiance in various fields in China, a large-area WC-C high temperature fixed-point blackbody system was set up at NIM, which is composed of a 14 mm diameter WC-C cell and a BB3500MP furnace with a radiator inner diameter of 59 mm in 2019 [20,21]. Based on the large area WC-C HTFP, NIM put forwarded a method for spectral irradiance measurement of the FEL lamp in the wavelength from 450 nm to 1000 nm [20].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation