1991
DOI: 10.1515/zna-1991-0511
|View full text |Cite
|
Sign up to set email alerts
|

A Microwave Fourier Transform Spectrometer in the Range from 18 to 26.4 GHz Increased Sensitivity Using Circular Waveguides. Measurements of Isotopomeres of Carbonylsulfide and of Methane

Abstract: A M ic ro w a v e F o u r ie r T r a n s fo rm S p e c tr o m e te r in th e R a n g e fro m 18 to 2 6 .4 G H z w ith I n c r e a s e d S e n s itiv ity U s in g C ir c u la r W a v e g u id e s. M e a s u r e m e n ts o f Is o to p o m e r e s o f C a rb o n y ls u lfid e a n d o f M e th a n e V. Meyer, W. Jäger, R. Schwarz, and H. Dreizler Abteilung Chemische Physik im Institut für Physikalische Chemie der Christian Albrechts Universität Kiel, Kiel Z. Naturforsch. 46a, 445-449 (1991); received February 21, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

1995
1995
2011
2011

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(8 citation statements)
references
References 8 publications
0
8
0
Order By: Relevance
“…Their general design is described elsewhere (23) and in references cited therein. Standard setups containing waveguide cells with rectangular or quadratic cross sections and lengths from 2 to 12 m have been used in the (26,27), have been employed. All measurements were performed at room temperature and sample pressures of about 0.1-0.7 Pa (1-5 mTorr).…”
Section: Resultsmentioning
confidence: 99%
“…Their general design is described elsewhere (23) and in references cited therein. Standard setups containing waveguide cells with rectangular or quadratic cross sections and lengths from 2 to 12 m have been used in the (26,27), have been employed. All measurements were performed at room temperature and sample pressures of about 0.1-0.7 Pa (1-5 mTorr).…”
Section: Resultsmentioning
confidence: 99%
“…A bridge-type construction also allows the use of oversized rectangular waveguides (Wolf and Mäder 1988). Using circular waveguides, even longer cells (>20 m, typically) can be employed by exploiting the very low loss circular TE 01 mode (Meyer et al 1991). An MW pin-diode switch (11c) protects the detection system from the highpower MW pulses.…”
Section: Stationary Gas Short-stimulus Signalmentioning
confidence: 99%
“…Further details on the spectrometer are given by Krüger et al (1993) and Meyer et al (1991). Xu & Lovas (1997); see also the discussion.…”
Section: Cologne and Kiel Laboratory Measurementsmentioning
confidence: 99%