Abstract: A newly developed compact and mobile time-of-flight mass spectrometer (TOFMS) for on-line analysis and monitoring of complex gas mixtures is presented. The instrument is designed for a (quasi-)simultaneous application of three ionization techniques that exhibit different ionization selectivities. The highly selective resonance-enhanced multiphoton ionization (REMPI) technique, using 266-nm UV laser pulses, is applied for selective and fragmentationless ionization of aromatic compounds at trace levels (parts-pe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
132
0
1

Year Published

2003
2003
2020
2020

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 124 publications
(135 citation statements)
references
References 62 publications
1
132
0
1
Order By: Relevance
“…4 with the associated vehicle speeds in the JC08 mode. We focused on the emission profiles of benzene and toluene since no other hydrocarbons with m/z = 78 and 92 were observed by GC/MS in this study and in previous exhaust measurements by Butcher et al 19 and Mühlberger et al 21 Two test runs in the JC08 mode were performed to confirm the reproducibility of the temporal emission profiles of benzene and toluene. In the gasoline vehicle exhaust, high concentrations of benzene and toluene were measured within the first few minutes, shown in Figs.…”
Section: Resultsmentioning
confidence: 92%
See 3 more Smart Citations
“…4 with the associated vehicle speeds in the JC08 mode. We focused on the emission profiles of benzene and toluene since no other hydrocarbons with m/z = 78 and 92 were observed by GC/MS in this study and in previous exhaust measurements by Butcher et al 19 and Mühlberger et al 21 Two test runs in the JC08 mode were performed to confirm the reproducibility of the temporal emission profiles of benzene and toluene. In the gasoline vehicle exhaust, high concentrations of benzene and toluene were measured within the first few minutes, shown in Figs.…”
Section: Resultsmentioning
confidence: 92%
“…Although N2 is not ionized by 10.5 eV SPI, it can be ionized by LEI; i.e., collisions with electrons emitted by the photoelectric effect and accelerated by the ion optics. 21,28 Broad signals at m/z = 32 and 44 in each figure are from O2 and CO2, respectively, which are also ionized by LEI.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…[5][6][7] In TOFMS, several ionization sources are in use: electron ionization (EI), 8 single photon ionization (SPI) with vacuum ultraviolet (VUV) photons, [9][10][11][12][13] and multiphoton ionization (MPI) with ultraviolet (UV) photons. [13][14][15][16] MPI/TOFMS combines a high selectivity for aromatic compounds with a high tolerance to contamination. 17,18 In environmental analysis, both content and concentration in real samples are, of course, unknown before measurement.…”
Section: Introductionmentioning