2013
DOI: 10.1088/0953-4075/46/16/164007
|View full text |Cite
|
Sign up to set email alerts
|

A modular end-station for atomic, molecular, and cluster science at the low density matter beamline of FERMI@Elettra

Abstract: The low density matter end-station at the new seeded free electron laser FERMI@Elettra is a versatile instrument for the study of atoms, molecules and clusters by means of electron and ion spectroscopies. Beams of atoms, molecules and helium droplets as well as clusters of atoms, molecules and metals can be produced by three different pulsed valves. The atomic and molecular beams may be seeded, and the clusters and droplets may be pure, or doped with other atoms and molecules. The electrons and ions produced b… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
79
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 88 publications
(79 citation statements)
references
References 27 publications
0
79
0
Order By: Relevance
“…The VMI spectrometer includes a 75 mm diameter imaging quality multichannel plate (MCP) stack with a high quality camera for the MCP image readout 31 . Its electron optics were set to work optimally for the kinetic energies of the He 1s electrons given by E kin ¼ E hn (48.4 eV) À E He(1s) (24.6 eV) ¼ 23.8 eV.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The VMI spectrometer includes a 75 mm diameter imaging quality multichannel plate (MCP) stack with a high quality camera for the MCP image readout 31 . Its electron optics were set to work optimally for the kinetic energies of the He 1s electrons given by E kin ¼ E hn (48.4 eV) À E He(1s) (24.6 eV) ¼ 23.8 eV.…”
Section: Methodsmentioning
confidence: 99%
“…Calibration was achieved by analyzing the electron emission of different noble gas targets at various photon energies. A pulsed, supersonic helium injection beam produced with a commercial Even-Lavie valve (aperture 100 mm) was used to provide sufficient gas density (about 10 12 atoms per cm 3 ) in the interaction region for a shot-to-shot analysis of the VMI-spectra 31 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This oscillates as a function of the relative phase η between the two harmonics, and its amplitude is approximately √ c( c) instead of c. The experiment was performed at the Low Density Matter beamline [17] of FERMI. The sample consisted of a mixture of neon and helium (for calibration purposes) and was exposed to a bichromatic beam of temporally overlapping first and second harmonic radiation with controlled phase relationship [14].…”
mentioning
confidence: 99%
“…For this reason, three dedicated experiments were carried out at two different FERMI beamlines, namely DiProI [9] and LDM. Activity on DiProI is focused on coherent imaging techniques, LDM is the FERMI beamline for atomic, molecular and cluster physics studies [21]. DiProI hosted two experimental setups: an optical VUV polarimeter [15][16][17]19] (see also Figure 2) and a polarimeter based on the measurement of the angular distribution of photoelectrons (form He 1s core level).…”
Section: Experimental Methods For Vuv Polarimetry At Fermimentioning
confidence: 99%