2021
DOI: 10.1016/j.microc.2021.106339
|View full text |Cite
|
Sign up to set email alerts
|

A molecularly imprinted polymer on reduced graphene oxide-gold nanoparticles modified screen-printed electrode for selective determination of ferulic acid in orange peels

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
10
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 41 publications
(11 citation statements)
references
References 46 publications
1
10
0
Order By: Relevance
“…The number of examples using a molecularly imprinted polymer as the key recognition element was comparable to that of the enzyme-based sensors [ 115 , 122 , 123 , 124 , 173 , 174 , 186 , 191 , 193 , 196 ], indicating that it could represent a promising synthetic receptor to be used instead of a “classical” enzyme.…”
Section: Discussionmentioning
confidence: 95%
See 2 more Smart Citations
“…The number of examples using a molecularly imprinted polymer as the key recognition element was comparable to that of the enzyme-based sensors [ 115 , 122 , 123 , 124 , 173 , 174 , 186 , 191 , 193 , 196 ], indicating that it could represent a promising synthetic receptor to be used instead of a “classical” enzyme.…”
Section: Discussionmentioning
confidence: 95%
“…Several examples introduced screen-printed carbon electrodes, modified with different gold nanomaterials [ 75 , 84 , 85 , 88 , 89 , 93 , 109 , 114 , 115 , 147 , 148 , 161 , 172 , 173 , 186 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Such devices possess a miniaturized system consisting of the working, auxiliary, and reference electrodes. Hence, there is a need for the small volume of solution for electrochemical determination, which is indeed interesting in terms of green chemistry [ 39 , 40 ]. Chemically modified electrodes (CMEs) are the result of the intentional fixation of a modifying agent on the surface of electrode by various physical and chemical methods [ 41 , 42 ].…”
Section: Introductionmentioning
confidence: 99%
“…However, the analytical characteristics obtained are sufficient for application to plant samples analysis. Regarding selectivity, the most impressive data were obtained using electrodes modified with molecularly imprinted polymers [158,172,174]. Although, other electrodes for flavonoids and phenolic acids determination [146][147][148][149][150][151][152][153][154][155][156][157][158][160][161][162][164][165][166][167][168][173][174][175]178] also show high selectivity in the presence of structurally related antioxidants that is caused by the type of modifier and conditions of electrochemical measurements (supporting electrolyte type and pH, electrochemical window, potential scan rate, etc.…”
mentioning
confidence: 99%