Abstract:The Von Mises equivalent stress criteria is used to equivalent convert and correct the uniaxial and biaxial fatigue reliability experimental study of the casing material. And the probabilistic fatigue P–S–N curve of the casing is gained. The fatigue limit and fatigue life in test is equivalent convert to actual casing by combined stress correction factor. A multiaxial fatigue life calculation formula is proposed by correcting the probabilistic fatigue P–S–N curve.
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.