A Multicenter Study of Removed Uric Acid Estimated by Ultra Violet Absorbance in the Spent Dialysate

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2009
2009
2012
2012

Publication Types

Select...
2
2
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 8 publications
0
5
0
Order By: Relevance
“…A good possibility to estimate UA concentrations using UV technique has shown in earlier studies [15] but if we use some signal processing tools we can essentially improve the accuracy and reliability of the results. Linear correlation coefficient r between laboratorial and calculated values of UA is slightly higher in case of the UV_D compared to the UV_A (0.95 vs. 0.94).…”
Section: Discussionmentioning
confidence: 96%
See 2 more Smart Citations
“…A good possibility to estimate UA concentrations using UV technique has shown in earlier studies [15] but if we use some signal processing tools we can essentially improve the accuracy and reliability of the results. Linear correlation coefficient r between laboratorial and calculated values of UA is slightly higher in case of the UV_D compared to the UV_A (0.95 vs. 0.94).…”
Section: Discussionmentioning
confidence: 96%
“…Ten uremic patients, three females and seven males, mean age 62.6 ± 18.6 years, were included in the study at the Department of Dialysis and Nephrology, North-Estonian Medical Centre, Estonia and 10 uremic patients, four females and six males, mean age 62.8 ± 20.9 years were included at the Department of Nephrology, University Hospital of Linköping, Sweden, using the clinical set-up of the experiments as described earlier [15]. All patients were on chronic thrice-weekly haemodialysis.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…A good way of estimating UA concentrations using the UV technique has been shown in previous studies [ 13 , 14 , 16 20 ], but if we use signal processing tools and absorbance information from several wavelengths, we can essentially improve the accuracy and reliability of the results.…”
Section: Discussionmentioning
confidence: 99%
“…Ways of monitoring UA, dialysate, and other biological fluids with optical tools have been shown previously by our and other groups [ 13 15 ]. If you use a simple signal processing tool for smoothing and calculating the first derivate of UV absorbance and/or absorbance or processed absorbance values from several wavelengths, more reliable results are achieved [ 16 20 ]. An effective way of estimating UA concentrations using the UV technique has been shown in previous studies by our group.…”
Section: Introductionmentioning