2005
DOI: 10.1016/j.sna.2005.03.006
|View full text |Cite
|
Sign up to set email alerts
|

A multisensor in thick-film technology for water quality control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
59
2
4

Year Published

2010
2010
2024
2024

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 92 publications
(65 citation statements)
references
References 11 publications
0
59
2
4
Order By: Relevance
“…k is the output nodes (k: 1-7). j is the hidden nodes (j: [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20]: Because the output function is a Tansig, the output has a value in the range [-1,1] so they must be made to fit among [0,1] using Eq. (2).…”
Section: Implementation Of the Multi-layer Feed-forward Neural Networkmentioning
confidence: 99%
See 1 more Smart Citation
“…k is the output nodes (k: 1-7). j is the hidden nodes (j: [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20]: Because the output function is a Tansig, the output has a value in the range [-1,1] so they must be made to fit among [0,1] using Eq. (2).…”
Section: Implementation Of the Multi-layer Feed-forward Neural Networkmentioning
confidence: 99%
“…A method for obtaining a multi-electrode of easy construction and simple operation is to employ inks from thick-film hybrid circuit technology [10] because there are many different types of inks and each has a key chemical element that can become the active element of the sensor.…”
Section: Introductionmentioning
confidence: 99%
“…Water quality monitoring demands the determination of water quality parameters like pH, dissolved oxygen, conductivity, turbidity, temperature, content of ammonia, metal ions, etc. [1][2][3][4][5]. The determination of pH being the measure of acidity or basicity of a solution is important in many chemical and biological reactions [6][7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…These electrodes have mechanical fragility, difficulty of miniaturization, chemical instability in corrosive systems and response dependence on pressure and temperature. Researchers have been trying for a long time to overcome these problems and develop a new pH measurement system which could be also helpful for making a new generation of wireless pH sensors for online monitoring of water quality [1,2,13,14] yttria stabilized zirconia (YSZ), perovskite materials, like lithium lanthanum titanate, etc., were used for this application [10,11,[15][16][17][18][19][20][21][22][23][24]. A few of publications reported on RuO 2 based [4,[25][26][27][28][29] pH sensors for online pH monitoring of water.…”
Section: Introductionmentioning
confidence: 99%
“…A raíz de nuestro interés en el diseño del sistema de detección 195,196,197,198,199 hemos desarrollado una lengua electrónica voltamétrica simple que se ha utilizado para caracterizar el tratamiento de las aguas afluentes y efluentes para una planta depuradora de aguas residuales domésticas. El sistema propuesto consiste en una array de electrodos metálicos formado por Au, Pt, Ir, Rh, Ag, Cu, Ni y Co y su uso como electrodos de trabajo en los experimentos de voltametría.…”
Section: Capítulounclassified