A multivariate calibration procedure for UV/VIS spectrometric quantification of organic matter and nitrate in wastewater

Abstract: A submersible UV/VIS spectrometer for in-situ real-time measurements is presented. It utilises the UV/VIS range (200-750 nm) for simultaneous measurement of COD, filtered COD, TSS and nitrate with just a single instrument. A global calibration is provided that is valid for typical municipal wastewater compositions. Usually high correlation coefficients can be achieved using this standard setting. By running a local calibration improvements concerning trueness, precision and long term stability of the results c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
119
0
12

Year Published

2007
2007
2019
2019

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 157 publications
(138 citation statements)
references
References 2 publications
4
119
0
12
Order By: Relevance
“…This instrument is a portable ultraviolet-visible spectrometer that measures light attenuation between 200 nm and 750 nm at 3-nm intervals and is designed for unattended use in natural and industrial environments (Langergraber et al 2003). The spectrolyser uses two beams from a Xenon lamp, one passing through the sample and one as a reference.…”
Section: Methodsmentioning
confidence: 99%
“…This instrument is a portable ultraviolet-visible spectrometer that measures light attenuation between 200 nm and 750 nm at 3-nm intervals and is designed for unattended use in natural and industrial environments (Langergraber et al 2003). The spectrolyser uses two beams from a Xenon lamp, one passing through the sample and one as a reference.…”
Section: Methodsmentioning
confidence: 99%
“…6 Acceptability criteria shall be established for calibration purposes. A simple criterion, for laboratory linear instruments, is the correlation coefficient of the regression model.…”
Section: Calibration and Verification Procedures 31 A Unified Calibrmentioning
confidence: 99%
“…The method and procedure used in the global calibration is presented by Langergraber et al [6]. Fig.…”
Section: Global Calibration Of Spectro::lyser Spectrophotometermentioning
confidence: 99%
“…By recording the light absorption in a sample between 200-400nm, the probe is capable of determining more than simply a fingerprint spectrum; besides this fingerprint, the values for a number of specific parameters are calculated from the data contained in the fingerprint, using algorithms provided by S::can [8,9].…”
Section: Figurementioning
confidence: 99%