2012
DOI: 10.1016/j.nimb.2011.12.004
|View full text |Cite
|
Sign up to set email alerts
|

A National project for in vivo dosimetry procedures in radiotherapy: First results

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
43
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 31 publications
(44 citation statements)
references
References 21 publications
1
43
0
Order By: Relevance
“…In this context, the strength of our method is twofold. First of all, our method adopts a generalized algorithm that can be easily implemented with a minimal workload for all Varian, Elekta and Siemens linacs and related EPIDs, with a few commissioning measurements time reduced to less than 30 minutes per linac [14,16]. Secondly, the software is interfaced with the Record&Verify system of the radiotherapy unit, allowing a direct and fast access to EPID images and treatment planning network.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…In this context, the strength of our method is twofold. First of all, our method adopts a generalized algorithm that can be easily implemented with a minimal workload for all Varian, Elekta and Siemens linacs and related EPIDs, with a few commissioning measurements time reduced to less than 30 minutes per linac [14,16]. Secondly, the software is interfaced with the Record&Verify system of the radiotherapy unit, allowing a direct and fast access to EPID images and treatment planning network.…”
Section: Discussionmentioning
confidence: 99%
“…This research led to the foundation of an Italian national project financed by the Istituto Nazionale di Fisica Nucleare (INFN) and the Diso software was extensively applied in clinical routine in several Italian centers. The first clinical results showed that IVD has a unique feature to assess all clinically relevant differences between planned and delivered dose, detecting the presence of dose discrepancies in 10% of the tests, mainly due to incorrect set-ups, presence of attenuators on the beams path and patient morphological changes [16]. Recently, the results of a 3-year experience including more than 1300 patients at Catholic University in Rome reported again about 10% of all IVD checks out of 5% tolerance level [17].…”
Section: Introductionmentioning
confidence: 99%
“…7) and the TMRM ratios (Eq. 8) were fitted by polynomial functions using a software package that minimize the sum of the residuals squares that are the differences between the experimental and the computed values [23]. …”
Section: Resultsmentioning
confidence: 99%
“…The method is based on the correlation ratios between the EPID transit signals and the doses at the isocenter point of SPs. The recent results [8, 23] are obtained for the 3D-CRT beams encouraged for the application in IMRT to develop a IVD procedure for Varian dynamic IMRT beams, based on a generalized algorithm. Correlation functions have been obtained irradiating SPs of different thicknesses, w  = 12, 22, 32, 42, 52 cm by a set of square simulated IMRT beams with L  = 5, 10, 12 and 17 cm at the SAD (Sect.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation