2002
DOI: 10.1100/tsw.2002.87
|View full text |Cite
|
Sign up to set email alerts
|

A New All-Season Passive Sampling System for Monitoring H2S in Air

Abstract: A new Maxxam All-Season Passive Sampling system for monitoring H2S in air has been developed. This passive sampling system employs the same approaches as the Maxxam All-Season Passive Sampling Systems for monitoring SO2, NO2, and O3 reported previously. This system has been extensively tested in the lab (temperature from -20 to 20°C, relative humidity from 30 to 84%, and wind speed from 0.5 to 150 cm/s) and validated in field studies. Comparing measurements obtained with the use of the new passive sampling sys… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0

Year Published

2006
2006
2018
2018

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(24 citation statements)
references
References 22 publications
0
24
0
Order By: Relevance
“…The all-season SO 2 passive sampling system (SPSS) (Tang et al, 1997), all-season NO 2 passive sampling system (NPSS) (Tang et al, 1999) and O 3 passive sampling system (OPSS) (Tang and Lau, 2000) were used to measure SO 2 , NO 2 and O 3 . As shown in Fig.…”
Section: Sampling and Analysismentioning
confidence: 99%
“…The all-season SO 2 passive sampling system (SPSS) (Tang et al, 1997), all-season NO 2 passive sampling system (NPSS) (Tang et al, 1999) and O 3 passive sampling system (OPSS) (Tang and Lau, 2000) were used to measure SO 2 , NO 2 and O 3 . As shown in Fig.…”
Section: Sampling and Analysismentioning
confidence: 99%
“…Therefore, the key factor for using passive samplers is how to determine their sampling rates. Tang et al have reported using equations to address the problems [4][5][6][7]. Field applications demonstrate that Tang's approach was practically useful in many cases.…”
Section: Amec Multigas Passive Sampling System -A Patented Technologymentioning
confidence: 99%
“…Their disadvantages are low sensitivity, inability to resolve short duration 15 concentration peaks, and adverse effects of meteorological conditions on reported observations (Tang et al 1997(Tang et al , 1999Krupa and Legge, 2000;Tang, 2001;Kirby et al, 2001;Partyka et al, 2007;Fraczek et al, 2009;Salem et al, 2009;Zabiegala et al, 2010). Moreover, the passive monitors depend on monthly meteorological information, needed in order to calculate diffusion rates.…”
Section: Monitoring Datamentioning
confidence: 99%
“…In contrast, passive sampling is carried out in order to determine monthly average ambient air concentrations of atmospheric 5 compounds for determination of long-term trends, assessment of potential ecological exposure risks, and to understand the spatial distribution of the measured pollutant. The majority of the Alberta passive monitors for NO 2 and SO 2 were developed by Maxxam Analytics Inc. (Tang et al, 1997;Tang et al, 1999;Tang, 2001), with the exception of those employed by PAS (PAS, 2016). The detection limit for 30-day average NO 2 and SO 2 sampling periods with these samplers is 0.1 ppbv.…”
Section: Monitoring Datamentioning
confidence: 99%