2014
DOI: 10.1039/c3ja50369k
|View full text |Cite
|
Sign up to set email alerts
|

A new closed-vessel conductively heated digestion system: fostering plant analysis by inductively coupled plasma optical emission spectroscopy

Abstract: A high-throughput, low cost and efficient device based on conductive heating and closed-vessels was developed and applied to plant digestion.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 21 publications
0
5
0
Order By: Relevance
“…During digestion, the main product NO 2 reacts with O 2 and H 2 O to regenerate HNO 3 . Nitric acid regeneration removes the excess of NO 2 from the gaseous phase and reduces the risks of overpressure (Miranda et al 2014a). In the CHDS, an immersed temperature sensor is not mandatory because the heat transfer is limited by the temperature of the aluminum heating block.…”
Section: Resultsmentioning
confidence: 99%
“…During digestion, the main product NO 2 reacts with O 2 and H 2 O to regenerate HNO 3 . Nitric acid regeneration removes the excess of NO 2 from the gaseous phase and reduces the risks of overpressure (Miranda et al 2014a). In the CHDS, an immersed temperature sensor is not mandatory because the heat transfer is limited by the temperature of the aluminum heating block.…”
Section: Resultsmentioning
confidence: 99%
“…According to the results obtained, it is possible to digest plant materials with the CHDS without pressure and temperature control. This is attained by performing a predigestion, limiting the sample mass to 200 mg, using an adequate amount of hydrogen peroxide in the acid mixture to remove NO 2 from the gaseous phase 9 and optimizing a heating program with target temperatures, ramps and hold times. In the CHDS, the heat transfer is limited by the temperature of the aluminum heating block.…”
Section: Resultsmentioning
confidence: 99%
“…9 A closed vessel microwave (MW) digestion system (Multiwave, Anton Paar, Graz, Austria) equipped with a rotor for 6 reaction PFA vessels (internal volume of 50 mL, minimum lling volume of 6 mL) and a temperature sensor was employed for comparison of digestion efficiency. Details about this system are described elsewhere.…”
Section: Instrumentationmentioning
confidence: 99%
“…Calibration curves were drawn from the 0, 5, 10, 20, 50, 100, 200, 500 and 1000 ppb standard solutions. The total metal concentrations were determined by Inductively Coupled Plasma (ICP-MS) Agilent Technologies 7700 series ICP-MS 16,[49][50][51] .…”
Section: Heavy Metal Analysismentioning
confidence: 99%