2008
DOI: 10.1016/j.jneumeth.2008.08.013
|View full text |Cite
|
Sign up to set email alerts
|

A new concept of a unified parameter management, experiment control, and data analysis in fMRI: Application to real-time fMRI at 3T and 7T

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
15
0
2

Year Published

2009
2009
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 19 publications
(17 citation statements)
references
References 19 publications
0
15
0
2
Order By: Relevance
“…An eight-element phased array coil (Siemens Medical Systems, Erlangen, Germany) was used for imaging. The vendor's EPI BOLD sequence and the corresponding reconstruction programs were modified to export each volume dataset immediately after acquisition and internal motion correction in real time to the host computer of the MRI scanner (Posse et al, 1999;Weiskopf et al, 2004Weiskopf et al, , 2007Hollmann et al, 2008). This software function performs the image export to any accessible computer in the local area network.…”
Section: Experimental Infrastructurementioning
confidence: 99%
“…An eight-element phased array coil (Siemens Medical Systems, Erlangen, Germany) was used for imaging. The vendor's EPI BOLD sequence and the corresponding reconstruction programs were modified to export each volume dataset immediately after acquisition and internal motion correction in real time to the host computer of the MRI scanner (Posse et al, 1999;Weiskopf et al, 2004Weiskopf et al, , 2007Hollmann et al, 2008). This software function performs the image export to any accessible computer in the local area network.…”
Section: Experimental Infrastructurementioning
confidence: 99%
“…We implemented a real-time fMRI-classification experiment based on the experimental description language EDL (Hollmann et al, 2008). Data acquisition was performed with the same parameters as in the offline experiment except for shorter TRs.…”
Section: Methodsmentioning
confidence: 99%
“…Data acquisition was performed with the same parameters as in the offline experiment except for shorter TRs. The MR scanners' EPI scanning protocol was modified to immediately export the acquired and motion corrected volumes (Hollmann et al, 2008). On the classification host, transformation matrices for spatial normalization were calculated from the first acquired EPI-volume and applied to all subsequently acquired volumes.…”
Section: Methodsmentioning
confidence: 99%
“…Magnetfeldst ä rken von 3 -4 Tesla scheinen zurzeit der bestm ö gliche Kompromiss zwischen der Verbesserung der Signalst ä rke und der Vermeidung von Messartefakten zu sein [4,5] . Allerdings hat Ultra-Hoch-Feld fMRT ( ≥ 7 T) ü ber die letzten Jahre starke Fortschritte gemacht und k ö nnte somit Grundlage f ü r die n ä chste Generation von Echtzeit-fMRT werden [6] . Auch bez ü glich der Messparameter , wie zum Beispiel der Bildaufl ö sung, gilt es, einen Kompromiss zwischen einer m ö glichst schnellen Bildakquisition, einer m ö glichst hohen Bildaufl ö sung und der Vermeidung von dadurch auftretenden Bildverzerrungen zu fi nden [7] .…”
Section: Introductionunclassified