A New Decellularization Protocol of Porcine Aortic Valves Using Tergitol to Characterize the Scaffold with the Biocompatibility Profile Using Human Bone Marrow Mesenchymal Stem Cells

Abstract: The most common aortic valve diseases in adults are stenosis due to calcification and regurgitation. In pediatric patients, aortic pathologies are less common. When a native valve is surgically replaced by a prosthetic one, it is necessary to consider that the latter has a limited durability. In particular, current bioprosthetic valves have to be replaced after approximately 10 years; mechanical prostheses are more durable but require the administration of permanent anticoagulant therapy. With regard to pediat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 7 publications
(11 citation statements)
references
References 23 publications
0
11
0
Order By: Relevance
“…Primarily, the thickness of each tissue sample was measured using Mitutoyo digital Caliber model ID-C112XB (Aurora, IL, USA), and later, the test for the uniaxial tensile property was performed with a customized apparatus (IRS, Padova, Italy) aided by a LabVIEW software (National Instruments, Austin, TX, USA). Tests were carried out as previously described [ 26 , 27 ]. Briefly, the samples were preloaded to 0.1 N at room temperature, then stretched until ruptured at the rate of 0.2 mm/s.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Primarily, the thickness of each tissue sample was measured using Mitutoyo digital Caliber model ID-C112XB (Aurora, IL, USA), and later, the test for the uniaxial tensile property was performed with a customized apparatus (IRS, Padova, Italy) aided by a LabVIEW software (National Instruments, Austin, TX, USA). Tests were carried out as previously described [ 26 , 27 ]. Briefly, the samples were preloaded to 0.1 N at room temperature, then stretched until ruptured at the rate of 0.2 mm/s.…”
Section: Methodsmentioning
confidence: 99%
“…In order to better characterize the non-linear stress-strain curves obtained from each sample, two tensile moduli, E1 and E2, were calculated as the slope of the linear portion of the curve between 0–10% (elastin region) and 60–100% deformation (collagen region), respectively [ 26 , 28 ]. A t -test (GraphPad Prism Software, San Diego, CA, USA) was applied to calculate the statistical analysis.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Each pericardium was isolated as described by Aguiari et al [ 37 , 38 ] and then decellularized following the TRICOL method published by Spina et al [ 39 ], but using Tergitol instead of Triton X-100 with the same concentration (1–0.1% v / v ) [ 40 , 41 ]. Tergitol was proposed by the supplier (Sigma Aldrich, Saint Louis, MO, USA) as an alternative detergent: its effectiveness was assessed by treating some biological samples (e.g., cardiovascular tissues).…”
Section: Methodsmentioning
confidence: 99%
“…Triton-X 100 has been removed from the market since January 2021 for its endocrine-disrupting properties (ECHA, REACH), and a new protocol has been developed by our group, which is based on a new detergent called Tergitol 15-S 9. This is a non-ionic, linear-chain surfactant belonging to the series of ethoxylated secondary alcohols, which has received promising preliminary results in the decellularization process ( Faggioli et al, 2022 ; Todesco et al, 2022 ; Casarin et al, 2022 ). Unlike Triton X-100, Tergitol 15-S 9 is easily biodegradable, does not induce cytotoxicity, and, due to its chemical structure, has a much faster micelle formation mechanism, resulting in better wettability.…”