2002
DOI: 10.1016/s0003-4975(02)03963-2
|View full text |Cite
|
Sign up to set email alerts
|

A new expandable venous cannula for minimal access heart surgery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
19
0

Year Published

2004
2004
2014
2014

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 21 publications
(20 citation statements)
references
References 5 publications
1
19
0
Order By: Relevance
“…Furthermore, remote venous cannulation with self-expanding cannulas provides similar flows as central cannulation. As a matter of fact the pump flows achieved in this consecutive series of adult patients are in 97% on or above target (mean 113%), and as a result, augmentation using centrifugal pumps or vacuum is unnecessary as previously reported for randomized experimental studies [3,8] and smaller series for specific indications [4,5,9]. It has also been shown previously in a study comparing self-expanding cannulas (access orifice 30 F) to classic two-stage cannulas (access orifice 48 F), that blood flows more than 10% above the target of 2.4 l/m 2 can be achieved without additional blood trauma [6].…”
Section: Discussionmentioning
confidence: 56%
“…Furthermore, remote venous cannulation with self-expanding cannulas provides similar flows as central cannulation. As a matter of fact the pump flows achieved in this consecutive series of adult patients are in 97% on or above target (mean 113%), and as a result, augmentation using centrifugal pumps or vacuum is unnecessary as previously reported for randomized experimental studies [3,8] and smaller series for specific indications [4,5,9]. It has also been shown previously in a study comparing self-expanding cannulas (access orifice 30 F) to classic two-stage cannulas (access orifice 48 F), that blood flows more than 10% above the target of 2.4 l/m 2 can be achieved without additional blood trauma [6].…”
Section: Discussionmentioning
confidence: 56%
“…1 Of course, this new technique involves some difficulties for the surgeon such as reduced operative field and restricted access to the cannulation sites. 5,6 However, the design of this cannula ( Fig. A femoral venous cannulation is often used for this process.…”
mentioning
confidence: 99%
“…A femoral venous cannulation is often used for this process. 3,4,6 The target blood flow can be difficult to reach with a percutaneous cannula, which can lead to a problem such as vessel chattering, as reported in Toomasian and McCarthy's 3 study. 5,6 However, the design of this cannula ( Fig.…”
mentioning
confidence: 99%
“…This phenomenon was complemented by performing in vivo animal testing with the SC exhibiting a 20% greater flow rate capacity during passive and active venous drainage techniques [20]. Similar findings were encountered by Mueller et al [21] in a parallel bovine experiment. Undertaking clinical comparisons is difficult as once theoretical flow is attained, it is also maintained.…”
Section: Discussionmentioning
confidence: 90%