2019
DOI: 10.1039/c8ja00313k
|View full text |Cite
|
Sign up to set email alerts
|

A new experimental setup for time- and laterally-resolved X-ray absorption fine structure spectroscopy in a ‘single shot’

Abstract: A new, simple and adjustable setup allows scanning-free XAS for time-resolved studies of structural changes in chemical compounds.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(10 citation statements)
references
References 16 publications
0
10
0
Order By: Relevance
“…ZIF-8 is easily synthesized through simple precipitation reactions facilitated by mixing the ligand (2-methylimidazole) and zinc salt solution at room temperature ( Park et al, 2006 ; Beyer et al, 2016 , 2018b ; Kulow et al, 2019 ). ZIF-8 can be engineered to acquire bioactivity beyond that of zinc ions through encapsulation of drugs.…”
Section: Preparation Methods Of Mofs Suitable For Term Laboratories Amentioning
confidence: 99%
“…ZIF-8 is easily synthesized through simple precipitation reactions facilitated by mixing the ligand (2-methylimidazole) and zinc salt solution at room temperature ( Park et al, 2006 ; Beyer et al, 2016 , 2018b ; Kulow et al, 2019 ). ZIF-8 can be engineered to acquire bioactivity beyond that of zinc ions through encapsulation of drugs.…”
Section: Preparation Methods Of Mofs Suitable For Term Laboratories Amentioning
confidence: 99%
“…Numerous studies have been performed with the aim of improving the performance of these setups for different applications. [49][50][51][52] In dispersive-XAS there is no scanning involved, as the whole polychromatic beam interacts with the sample and is then diffracted by a crystal. This results in more beam position stability.…”
Section: Time Resolved Xas/xes (Quick-xas Dispersive-xas Ultrafast-xas)mentioning
confidence: 99%
“…The other approach is dispersive‐XAS, which consists of diffraction a polychromatic beam—of a specific bandwidth—by a bent crystal (e.g., Si 111). Numerous studies have been performed with the aim of improving the performance of these setups for different applications 49–52 . In dispersive‐XAS there is no scanning involved, as the whole polychromatic beam interacts with the sample and is then diffracted by a crystal.…”
Section: Modus Operandi and Applicationsmentioning
confidence: 99%
“…Thus, it is imperative to minimize the number of diffraction peaks during the experiment itself. This necessitates either minimizing the footprint of the beam on the diamond with a small and mechanically stable beam (Pascarelli et al, 2004(Pascarelli et al, , 2006(Pascarelli et al, , 2016Baudelet et al, 2011;Pascarelli & Mathon, 2010;Mathon et al, 2004Mathon et al, , 2015Kulow et al, 2019;Kantor et al, 2018) or replacing crystalline diamonds with (expensive) polycrystalline diamonds (Ishimatsu et al, 2012). The second problem with the DAC is a weakening of the signal-to-noise ratio (i.e.…”
Section: Introductionmentioning
confidence: 99%