2019
DOI: 10.1016/j.nima.2018.11.095
|View full text |Cite
|
Sign up to set email alerts
|

A new High-Resolution Imaging System (HiRIS2) detector for preclinical SPECT imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…The spatial resolution of clinical SPECT is 5–10 mm (Dewaraja et al 2012). Recently resolutions of 2.5 and 1.6 mm were reported in images of a phantom using a multi-pinhole clinical (Chen et al 2018) or preclinical (Massari et al 2019) SPECT system, respectively. However, for animal studies, it is possible to perform autoradiography in combination with immunohistochemical staining of excised tissues ex vivo to understand the heterogeneous radioactivity distribution in different regions of tumours and normal organs (Lee et al 2010).…”
Section: Dosimetric Propertiesmentioning
confidence: 99%
“…The spatial resolution of clinical SPECT is 5–10 mm (Dewaraja et al 2012). Recently resolutions of 2.5 and 1.6 mm were reported in images of a phantom using a multi-pinhole clinical (Chen et al 2018) or preclinical (Massari et al 2019) SPECT system, respectively. However, for animal studies, it is possible to perform autoradiography in combination with immunohistochemical staining of excised tissues ex vivo to understand the heterogeneous radioactivity distribution in different regions of tumours and normal organs (Lee et al 2010).…”
Section: Dosimetric Propertiesmentioning
confidence: 99%
“…The preclinical SPECT scanner presented in this work has been designed on the basis of an imaging system previously engineered by our group 5 . The detectors, named High-Resolution Imaging System (HiRIS2), have been developed using several Monte Carlo (MC) simulations to de ne the mechanical structure and compose the preparatory technical drawings 8 .…”
Section: Methodsmentioning
confidence: 99%
“…In this context, the need to develop imaging systems able to precisely visualize small details has arisen. Our research group has previously developed high-performance scintigraphic detectors for small animal imaging 5,6 . The feasibility of our patented method named Super Spatial Resolution (SSR) 7 has been simulated for its application on a scintigraphic system giving as a result planar or three-dimensional (3D) images with a resolution enhancement 8 .…”
Section: Introductionmentioning
confidence: 99%
“…The characterization of the sole HiRIS2 detector has been performed in our previous work by using complex patterns allowing the assessment of the spatial linearity and the overall imaging capability 5,6 . In this study, the HiRIS2 SPECT system performance was determined experimentally using a customdesigned polymethyl methacrylate (PMMA) phantom, and a glass capillary, both lled with a solution of 99m TcO 4 -( -ray 140.5 keV).…”
Section: Phantoms Evaluationmentioning
confidence: 99%