Abstract:A new on-line measurement system of dielectric loss angle (δ ) with FPGA for high voltage capacitive apparatus is presented in this paper. By using double polarity zero crossing point comparing method for measuring phase difference, system frequency measurement and measurement error adaptive corrected with FPGA is adopted. Tests results show that the measuring system based on FPGA is with higher precision, stability and anti-interference reliability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.