2023
DOI: 10.1016/j.sbsr.2023.100554
|View full text |Cite
|
Sign up to set email alerts
|

A non-toxic poly(resorcinol) modified glassy carbon electrode for highly selective square wave voltammetry determination of aspirin in tablet formulations and human urine samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
11
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 9 publications
(13 citation statements)
references
References 30 publications
2
11
0
Order By: Relevance
“…The oxidative peaks current of 1.0 m m CQP was increased with the increasing number of cycles, which may be due to the increase in effective surface area of GCE as a result of modification (Figure 2 ). [ 16 , 18 , 21 ] Even though a considerable enhancement of oxidative peaks current was observed at each cycle, largest increment with highest slope was recorded by 20 cycles (Inset of Figure 2 ), beyond 20 cycles slight increase of peak current suggests that the overdose of the complex film at the GCE reduces its interaction with the electroactive functional group of CQP due to the saturation of the active sites. Therefore, 20 cycles were selected as the optimal condition for preparation of poly(DHRPCo)/GCE for determination of CQP in human blood serum, human urine and pharmaceutical formulation samples.…”
Section: Resultsmentioning
confidence: 98%
See 4 more Smart Citations
“…The oxidative peaks current of 1.0 m m CQP was increased with the increasing number of cycles, which may be due to the increase in effective surface area of GCE as a result of modification (Figure 2 ). [ 16 , 18 , 21 ] Even though a considerable enhancement of oxidative peaks current was observed at each cycle, largest increment with highest slope was recorded by 20 cycles (Inset of Figure 2 ), beyond 20 cycles slight increase of peak current suggests that the overdose of the complex film at the GCE reduces its interaction with the electroactive functional group of CQP due to the saturation of the active sites. Therefore, 20 cycles were selected as the optimal condition for preparation of poly(DHRPCo)/GCE for determination of CQP in human blood serum, human urine and pharmaceutical formulation samples.…”
Section: Resultsmentioning
confidence: 98%
“…The observed current increment at pH 7.5 could partly be attributed the strong electrostatic attraction of the cationic CQP (p K a : 8.4), [1] with negatively charge poly(DHRPCo) film (phen, and reso with p K a values of 4.86&9.15, respectively). [ 16 , 18 , 21 ]…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations