1979
DOI: 10.1152/jappl.1979.46.2.399
|View full text |Cite
|
Sign up to set email alerts
|

A noninvasive technique for measurement of changes in specific airway resistance

Abstract: A simple noninvasive technique for measuring specific airway resistance (airway resistance X thoracic gas volume) in unanesthetized guinea pigs is described. Specific airway resistances measured by this technique correlated well (r = 0.81) with the resistances obtained using a pleural catheter pressure measurement over a wide range of airway resistances. This range of resistances was generated by exposing the pigs to an aerosolized histamine bronchial challenge. The average specific airways resistance in uncha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
159
0
1

Year Published

2001
2001
2012
2012

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 278 publications
(161 citation statements)
references
References 0 publications
1
159
0
1
Order By: Relevance
“…Pulmonary Function Measurements sRaw was measured in conscious guinea pigs by a two-chambered, doubleflow plethysmograph system in accordance with the method of Pennock et al 29) In brief, an animal was placed with its neck extending through the partition of a two-chambered box, and after detection of airflow by sensors attached to both the front and rear chambers, sRaw was then measured using a Data Analyzer Pulmos-I device (M.I.P.S., Osaka).…”
Section: Methodsmentioning
confidence: 99%
“…Pulmonary Function Measurements sRaw was measured in conscious guinea pigs by a two-chambered, doubleflow plethysmograph system in accordance with the method of Pennock et al 29) In brief, an animal was placed with its neck extending through the partition of a two-chambered box, and after detection of airflow by sensors attached to both the front and rear chambers, sRaw was then measured using a Data Analyzer Pulmos-I device (M.I.P.S., Osaka).…”
Section: Methodsmentioning
confidence: 99%
“…To evaluate the degree of early-and late-phase increases in airway resistance, specific airway resistance [sRaw; cmH 2 O 3 mL/(mL/s)] was measured in conscious mice before and 10 min to 5 h after the first and fourth challenges using a two-chambered, double-flow plethysmograph system (Pulmos-I; M.I.P.S., Osaka, Japan) according to the method of Pennock et al (32).…”
Section: Measurement Of Airway Resistancementioning
confidence: 99%
“…The noninvasive technique is based on measurement of the time delay between thoracic and mouth volume changes, and we calculated the airway resistance (30,31). Airway responsiveness to i.v.…”
Section: Measurement Of Specific Airway Responsiveness (Sraw)mentioning
confidence: 99%