2011
DOI: 10.1007/s13361-011-0141-9
|View full text |Cite
|
Sign up to set email alerts
|

A Novel 9.4 Tesla FTICR Mass Spectrometer with Improved Sensitivity, Mass Resolution, and Mass Range

Abstract: Fourier transform ion cyclotron resonance (FTICR) mass spectrometry provides unparalleled mass measurement accuracy and resolving power. However, propagation of the technique into new analytical fields requires continued advances in instrument speed and sensitivity. Here, we describe a substantial redesign of our custom-built 9.4 tesla FTICR mass spectrometer that improves sensitivity, acquisition speed, and provides an optimized platform for future instrumentation development. The instrument was designed arou… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
208
0

Year Published

2012
2012
2018
2018

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 207 publications
(209 citation statements)
references
References 55 publications
1
208
0
Order By: Relevance
“…38,39,43 The latter procedures are typically applied to soil, plant or algal organic matter, but were used here to characterize the sand patty-derived DOM. Clearly, the organic matter in sand patties However, there is only a 24% degree of similarity between the plots depicted in Figure 4A and 4C.…”
Section: Chemical Characterization Of Dom Biodegradationmentioning
confidence: 99%
“…38,39,43 The latter procedures are typically applied to soil, plant or algal organic matter, but were used here to characterize the sand patty-derived DOM. Clearly, the organic matter in sand patties However, there is only a 24% degree of similarity between the plots depicted in Figure 4A and 4C.…”
Section: Chemical Characterization Of Dom Biodegradationmentioning
confidence: 99%
“…histone samples were dissolved in 50% acetonitrile (H 2 O/CH 3 CN) (50/50) with 1.0% formic acid to reach a final concentration of 1.0 M and introduced into a custom-built 9.4 Tesla FT-ICR mass spectrometer via positive electrospray ionization (44). Both precursor and product ion spectra were acquired by direct infusion at the flow rate of 0.35 l/min.…”
Section: T Ft-icr Ms-preparedmentioning
confidence: 99%
“…However, the intact experimental mass for the first peak does not agree with the calculated H2B1C mass; thus, producing a false positive result, which we eliminate. ProSight Lite was conducted at the same time to validate our identifications (44).…”
Section: Transformation Of Cells By Low-dose Chronic Exposure Tomentioning
confidence: 99%
“…). The experiments were performed with a custom-built 9.4 T ESI FT-ICR mass spectrometer recently described in detail [54]. Samples were infused into a tapered 50 μm i.d.…”
Section: Theorymentioning
confidence: 99%