A novel and fast method for proton range verification using a step wedge and 2D scintillator

Abstract: Purpose: To implement and evaluate a novel and fast method for proton range verification by using a planar scintillator and step wedge. Methods: A homogenous proton pencil beam plan with 35 energies was designed and delivered to a 2D flat scintillator with a step wedge. The measurement was repeated 15 times (3 different days, 5 times per day). The scintillator image was smoothed, the Bragg peak and distal fall off regions were fitted by an analytical equation, and the proton range was calculated using simple t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 11 publications
(16 citation statements)
references
References 14 publications
0
16
0
Order By: Relevance
“…Prior to any film measurements, the WET was measured and benchmarked for all slabs of Solid Water ® individually as well as in groups horizontally aligned within the beamline. The WET was assessed for nominal proton beam energies of 125 and 163 MeV using a pull‐back range technique, which is an established method that has been used for beam range verification . The D90% range of the beam in water was measured using an IBA Zebra multilayer ionization chamber (MLIC) and OmniPro Incline software.…”
Section: Methodsmentioning
confidence: 99%
“…Prior to any film measurements, the WET was measured and benchmarked for all slabs of Solid Water ® individually as well as in groups horizontally aligned within the beamline. The WET was assessed for nominal proton beam energies of 125 and 163 MeV using a pull‐back range technique, which is an established method that has been used for beam range verification . The D90% range of the beam in water was measured using an IBA Zebra multilayer ionization chamber (MLIC) and OmniPro Incline software.…”
Section: Methodsmentioning
confidence: 99%
“…As shown in Fig. (a), the reproducibility on the same day is within 0.1 mm, which is already much better than the results from our preliminary work . This improved reproducibility is due to the strict selection of images captured by a single frame, which successfully removes the effect of the interframe dead time.…”