Abstract:Aquatic systems play a key role in the global antimony (Sb) cycle, but studies on the isotopic ratio of Sb in freshwater are very rare due to the low Sb...
“…A procedure for the isotopic analysis of Sb in water samples at low concentration (<1 μg L −1 ) involved 86 the addition of 200 μL of a 25% v/v BrCl solution to a 200 mL sample to digest all the DOM in the sample. A mixture of KI, hydroxylamine hydrochloride and ascorbic acid was added to this digest to remove excess BrCl and to convert any Sb V present to Sb III .…”
This review covers advances in the analysis of air, water, plants, soils and geological materials by a range of atomic spectrometric techniques including atomic emission, absorption, fluorescence and mass spectrometry.
“…A procedure for the isotopic analysis of Sb in water samples at low concentration (<1 μg L −1 ) involved 86 the addition of 200 μL of a 25% v/v BrCl solution to a 200 mL sample to digest all the DOM in the sample. A mixture of KI, hydroxylamine hydrochloride and ascorbic acid was added to this digest to remove excess BrCl and to convert any Sb V present to Sb III .…”
This review covers advances in the analysis of air, water, plants, soils and geological materials by a range of atomic spectrometric techniques including atomic emission, absorption, fluorescence and mass spectrometry.
“…The pre-concentration method is an effective method to solve the problem of insufficient sample concentration for accurate isotope measurements, but it involves complex operations. 30,31,[39][40][41] The FI technique is widely used for elemental analysis due to its advantages of low sample consumption and short analysis time. 31,35 Therefore, we assessed the feasibility of combining FI with PEVG as a microsampling technique to rapidly and accurately analyse Hg isotopes in samples with low Hg concentration.…”
Section: Establishment Of Fi-pevg-mc-icpms For Rapid Hg Isotope Analysismentioning
A new strategy for determining the Hg isotopes in low Hg concentration samples is proposed, utilizing the flow injection plasma electrochemical vapor generation (FI-PEVG) sampling technique coupled with MC-ICPMS. Our...
“…Hence, the Sb system could be used to trace sources of pollution, in particular in the aquatic environment. Xia et al 170 addressed the preparation of freshwater for Sb isotopic analysis, which has been difficult due to the low concentrations involved. Their study designed a novel preconcentration and purification system in which water samples were processed using KI-ascorbic acid Sb reduction prior to a vacuum-driven thiol resin ion exchange system.…”
This review covers advances in atomic spectrometric techniques, including atomic emission, absorption, fluorescence and mass spectrometry. Material on speciation and coupled techniques is not covered as this is included in a separate ASU review.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.