2023
DOI: 10.1039/d2ja00357k
|View full text |Cite
|
Sign up to set email alerts
|

A novel approach to sample preparation for the analysis of Sb isotope ratios in natural water by MC-ICP-MS

Abstract: Aquatic systems play a key role in the global antimony (Sb) cycle, but studies on the isotopic ratio of Sb in freshwater are very rare due to the low Sb...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 44 publications
0
3
0
Order By: Relevance
“…A procedure for the isotopic analysis of Sb in water samples at low concentration (<1 μg L −1 ) involved 86 the addition of 200 μL of a 25% v/v BrCl solution to a 200 mL sample to digest all the DOM in the sample. A mixture of KI, hydroxylamine hydrochloride and ascorbic acid was added to this digest to remove excess BrCl and to convert any Sb V present to Sb III .…”
Section: Water Analysismentioning
confidence: 99%
“…A procedure for the isotopic analysis of Sb in water samples at low concentration (<1 μg L −1 ) involved 86 the addition of 200 μL of a 25% v/v BrCl solution to a 200 mL sample to digest all the DOM in the sample. A mixture of KI, hydroxylamine hydrochloride and ascorbic acid was added to this digest to remove excess BrCl and to convert any Sb V present to Sb III .…”
Section: Water Analysismentioning
confidence: 99%
“…The pre-concentration method is an effective method to solve the problem of insufficient sample concentration for accurate isotope measurements, but it involves complex operations. 30,31,[39][40][41] The FI technique is widely used for elemental analysis due to its advantages of low sample consumption and short analysis time. 31,35 Therefore, we assessed the feasibility of combining FI with PEVG as a microsampling technique to rapidly and accurately analyse Hg isotopes in samples with low Hg concentration.…”
Section: Establishment Of Fi-pevg-mc-icpms For Rapid Hg Isotope Analysismentioning
confidence: 99%
“…Hence, the Sb system could be used to trace sources of pollution, in particular in the aquatic environment. Xia et al 170 addressed the preparation of freshwater for Sb isotopic analysis, which has been difficult due to the low concentrations involved. Their study designed a novel preconcentration and purification system in which water samples were processed using KI-ascorbic acid Sb reduction prior to a vacuum-driven thiol resin ion exchange system.…”
Section: Isotope Analysismentioning
confidence: 99%