2016
DOI: 10.3389/fphys.2016.00319
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Chip for Cyclic Stretch and Intermittent Hypoxia Cell Exposures Mimicking Obstructive Sleep Apnea

Abstract: Intermittent hypoxia (IH), a hallmark of obstructive sleep apnea (OSA), plays a critical role in the pathogenesis of OSA-associated morbidities, especially in the cardiovascular and respiratory systems. Oxidative stress and inflammation induced by IH are suggested as main contributors of end-organ dysfunction in OSA patients and animal models. Since the molecular mechanisms underlying these in vivo pathological responses remain poorly understood, implementation of experimental in vitro cell-based systems capab… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
50
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 39 publications
(52 citation statements)
references
References 58 publications
1
50
1
Order By: Relevance
“…To assess the potential sources of VEGF under IH conditions, 5x10 4 RENCA cells, 15x10 4 RAW 264.7 cells and 6x10 4 HAEC cells were exposed to IH (cycles alternating 20% O 2 −1% O 2 every 30 s) or continuous RA (21% O 2 ) as previously described [23]. After 24 h, total RNA from RENCA, RAW 264.7 and HAEC cell cultures were extracted using the RNeasy kit (Qiagen, Hilden, Germany).…”
Section: Methodsmentioning
confidence: 99%
“…To assess the potential sources of VEGF under IH conditions, 5x10 4 RENCA cells, 15x10 4 RAW 264.7 cells and 6x10 4 HAEC cells were exposed to IH (cycles alternating 20% O 2 −1% O 2 every 30 s) or continuous RA (21% O 2 ) as previously described [23]. After 24 h, total RNA from RENCA, RAW 264.7 and HAEC cell cultures were extracted using the RNeasy kit (Qiagen, Hilden, Germany).…”
Section: Methodsmentioning
confidence: 99%
“…Unlike in other microfluidic settings, cells are not in the chamber itself but rather are in direct contact with it by growing on a gas-permeable membrane, which allows for close control and fast equilibration of pericellular O 2 , while diminishing mechanical stress. Furthermore, the modulation of pressure in the chamber mediates a cyclical stretching of the cell culture that simulates the periodic expansion of the heart or lung (Figure 2D) (63). Using a similar principle, the development of a PDMS pillar with an oxygen perfusion channel, coated with Parylene-C to ensure better oxygen isolation and faster equilibration, has been reported.…”
Section: Flow-through Systems and Microfluidicsmentioning
confidence: 93%
“…Additionally, the meniscus of the medium forming within the culture well-causes a significant difference in the diffusion distance across the culture surface, which requires maintaining the cells in the middle of the well (62), which is difficult to achieve when using cell lines with significant proliferative capacity. Alternatively, researchers used stirring or shaking of the culture vessel as a simple method to increase oxygen diffusion (36), although this was at the cost of inducing mechanical stress to the cells (63).…”
Section: Sustained Hypoxia-diffusion Challengementioning
confidence: 99%
See 2 more Smart Citations