2015
DOI: 10.1016/j.snb.2014.09.039
|View full text |Cite
|
Sign up to set email alerts
|

A novel colorimetric sensor strip for the detection of glyphosate in water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
27
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 80 publications
(31 citation statements)
references
References 25 publications
3
27
1
Order By: Relevance
“…In recent years, ICS appears to be an easy and onsite membranebased immunoassay method with low cost, which has increasingly gained attention for the residue detection of pesticides (De Almeida, Chigome, Torto, Frost, & Pletschke, 2015), veterinary drugs , mycotoxins , pathogens (Leem, Shukla, Song, Heu, & Kim, 2014), heavy metal (Zhu et al, 2014), banned additives (Song et al, 2011), and even on disease diagnosis areas . The ICS now mostly employ colloidal gold as reporters for colorimetric detection which require no special equipment and reagents, and the visible results of ICS can judged by the naked eye.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, ICS appears to be an easy and onsite membranebased immunoassay method with low cost, which has increasingly gained attention for the residue detection of pesticides (De Almeida, Chigome, Torto, Frost, & Pletschke, 2015), veterinary drugs , mycotoxins , pathogens (Leem, Shukla, Song, Heu, & Kim, 2014), heavy metal (Zhu et al, 2014), banned additives (Song et al, 2011), and even on disease diagnosis areas . The ICS now mostly employ colloidal gold as reporters for colorimetric detection which require no special equipment and reagents, and the visible results of ICS can judged by the naked eye.…”
Section: Introductionmentioning
confidence: 99%
“…This method is highly sensitive compared to previous reports. For instance, a colorimetric method for the determination of glyphosate was developed, with LOD of 100 ng mL −1 [27]. Anion-exchange chromatography with coulometric detection was used for the determination of glyphosate and AMPA in water, and the LODs were 38 ng mL −1 for glyphosate, 240 ng mL −1 for APMA [28].…”
Section: Comparison To Previous Reportsmentioning
confidence: 99%
“…Colorimetric NP‐doped nanofibers have also been used for environmental monitoring. For example, Pletschke et al proposed a two‐step method to detect glyphosate with the help of copper‐doped poly(vinyl)alcohol nanofibers . Glyphosate is the most widely applied herbicide, but its use is restricted due to potential environmental impact and health hazards.…”
Section: Colorimetric Sensors Based On Doped Nanofibersmentioning
confidence: 99%