2019
DOI: 10.1016/j.jneumeth.2019.108405
|View full text |Cite
|
Sign up to set email alerts
|

A novel device to measure static hindlimb weight-bearing forces in pronograde rodents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(10 citation statements)
references
References 56 publications
0
10
0
Order By: Relevance
“…On the other hand, in the fields of nerve tissue regeneration and orthopedic research, evaluating the restoration of the leg function is performed by using the weight-bearing assessment. [64,65] This study histologically evaluated the muscle regeneration through Gel NF in vivo. In addition, it is worthwhile to evaluate the recovery of the leg function along with muscle regeneration by evaluating the weight-bearing during the recovery process.…”
Section: Resultsmentioning
confidence: 99%
“…On the other hand, in the fields of nerve tissue regeneration and orthopedic research, evaluating the restoration of the leg function is performed by using the weight-bearing assessment. [64,65] This study histologically evaluated the muscle regeneration through Gel NF in vivo. In addition, it is worthwhile to evaluate the recovery of the leg function along with muscle regeneration by evaluating the weight-bearing during the recovery process.…”
Section: Resultsmentioning
confidence: 99%
“…A separate cohort of mice received an intra-articular injection of either MIA (1 mg/10 μL) or saline (10 μL). A static horizontal incapacitance meter (SHIM) (15) was used to assess the percent of hindlimb supported body weight placed on each hindlimb. Mice placed significantly less weight on the injected limb compared to the contralateral limb starting at Day 2 and continuing to Day 28 (Figure 2a).…”
Section: Resultsmentioning
confidence: 99%
“…Static weight bearing was measured using a SHIM incapacitance meter (IC Meter) connected to a system 8000 micro-measurements tool (15). Data were collected from mice as described previously (15).…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Static weight-bearing was measured using a Static Hind limb Incapacitance Meter (SHIM) connected to a system 8000 MicroMeassurements tool (Williams et al, 2019), and also measured using the IITC Incapacitance Meter (IC Meter) (IITC, Life Science, Woodland Hills, CA, United States). For the SHIM, data were collected from mice as described previously (Williams et al, 2019). Data were retained if the animal stood still in a relaxed position, without noticeably shifting weight, lifting, offloading a limb, or turning the head.…”
Section: Incapacitance Meter To Measure Static Limb Usementioning
confidence: 99%