2020
DOI: 10.1016/j.molstruc.2020.128033
|View full text |Cite
|
Sign up to set email alerts
|

A novel dual chemosensor for selective heavy metal ions Al3+, Cr3+ and its applicable cytotoxic activity, HepG2 living cell images and theoretical studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 24 publications
(6 citation statements)
references
References 53 publications
0
6
0
Order By: Relevance
“…The protein was first prepared using the protein preparation wizard and the docking experiments within Maestro 9.5 were conducted using Schrodinger's Glide program. Ligand preparation was carried out using LigPrep, followed by the minimization and optimization of the force field for liquid simulations (Dodda et al, 2017). The G score was measured in kcal/mol, which included hydrogen bonds, internal strength, hydrophobic interactions, stacking interactions, ligand-protein interaction energies, and square deviation and desolvation of the center.…”
Section: Molecular Dockingmentioning
confidence: 99%
See 3 more Smart Citations
“…The protein was first prepared using the protein preparation wizard and the docking experiments within Maestro 9.5 were conducted using Schrodinger's Glide program. Ligand preparation was carried out using LigPrep, followed by the minimization and optimization of the force field for liquid simulations (Dodda et al, 2017). The G score was measured in kcal/mol, which included hydrogen bonds, internal strength, hydrophobic interactions, stacking interactions, ligand-protein interaction energies, and square deviation and desolvation of the center.…”
Section: Molecular Dockingmentioning
confidence: 99%
“…The cell viability (%) of the ligand and its various concentrations (Dhineshkumar et al, 2019) with its respective IC 50 values are given in Table 1. Plots of the HeLa cell line viability and the concentration of the ligand treatment are shown in Figure 12.…”
Section: The Cytotoxicity Activitymentioning
confidence: 99%
See 2 more Smart Citations
“…Compared with the above detection methods, fluorescence analysis has gradually become an effective tool in the field of analysis and detection, not only due to its advantages of high sensitivity, as well as low detection limit, but also owing to its visual recognition and low intracellular toxicity [18][19][20][21][22][23][24][25][26][27][28][29]. Considering some Al 3+ fluorescent probes suffer from unacceptable factors, such as the complex synthesis routes, interferences by other co-existence metal ions, and insolubility in water, Molecules 2022, 27, 2569 2 of 15 the development of an efficient Al 3+ fluorescent probe with high sensitivity, as well as good application prospects, still attracts worldwide attention [2,[30][31][32][33][34][35].…”
Section: Introductionmentioning
confidence: 99%