2018
DOI: 10.1016/j.ab.2018.06.010
|View full text |Cite
|
Sign up to set email alerts
|

A novel electrochemical DNA biosensor for Ebola virus detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
61
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 111 publications
(61 citation statements)
references
References 31 publications
0
61
0
Order By: Relevance
“…Recently, a novel electrochemical based biosensor for the detection of deadly EV-DNA had been successfully developed ( Ilkhani and Farhad, 2018 ). In this work, the DNA biosensor was fabricated using a thiolated DNA capture probe sequence immobilized onto the Au surface of screen-printed electrodes functionalized with thiolated single strand capture probe DNA (1 μM).…”
Section: Electrochemical Biosensors For Virus Detectionmentioning
confidence: 99%
“…Recently, a novel electrochemical based biosensor for the detection of deadly EV-DNA had been successfully developed ( Ilkhani and Farhad, 2018 ). In this work, the DNA biosensor was fabricated using a thiolated DNA capture probe sequence immobilized onto the Au surface of screen-printed electrodes functionalized with thiolated single strand capture probe DNA (1 μM).…”
Section: Electrochemical Biosensors For Virus Detectionmentioning
confidence: 99%
“… Electrochemical format Electrochemical format Genosensors R1: 32 pmol L-1 Genosensors R2: 9 pmol L-1 Genosensors R1: 0.7 pmol L-1 Genosensors R2: 3 pmol L-1 [77] Zika virus Chikungunya viruses -a Chikungunya viruses -b Multiplex RT-qPCR 100 copies 5 copies 50 copies [78] Porcine epidemic diarrhea virus Immuno-chromatographic strip 1:50 [79] H1N1 of influenza A virus H3N2 of influenza A virus CdSe/CdS/ZnS quantum dot-linked rapid fluorescent immunochromatographic test 28.37 34.48 [80] Epstein-Barr virus Electrochemical detection 0.46 fM [81] Pseudorabies virus Porcine circovirus 3 SYBR green I-based duplex real-time PCR 37.8 copies/μL, 30.6 copies/μL [82] Classic swine fever virus Porcine circovirus 3 SYBR green I-based duplex real-time fluorescence quantitative PCR 23 copies/μL 36 copies/μL [83] Ebola virus Rolling circle amplification of Ebola virus and fluorescence detection based on graphene oxide 1.4 pM. [84] Ebola virus Microfluidic sample preparation multiplex 0.021 pfu/mL [85] Ebola virus Electrochemical DNA biosensor 4.7nm [86] Ebola virus RT-PCR 10 molecules/μl …”
Section: Current Scenario In the Detection Of Virusesmentioning
confidence: 99%
“…36 For instance, a novel electrochemical-based nucleic acid sensor was fabricated for Ebola virus RNA detection (Figure 1B). 25 In the first step, the gold surface of screen-printed electrode was functionalized with a thiolated DNA capture probe sequence via S-Au bonding. Then, biotinylated target strand DNA was immobilized to the electrode surface for hybridization of thiolated DNA single strand capture.…”
Section: Nucleic Acid-based Sensorsmentioning