2002
DOI: 10.1016/s0022-0728(02)01209-3
|View full text |Cite
|
Sign up to set email alerts
|

A novel impedance spectrometer based on carrier function Laplace-transform of the response to arbitrary excitation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
36
0

Year Published

2003
2003
2023
2023

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 34 publications
(36 citation statements)
references
References 17 publications
0
36
0
Order By: Relevance
“…The model of the overvoltage is obtained from an equivalent circuit, R s C bat (RC) 1 (RC) 2 (RC) 3 (RC) 4 , where R is a resistor and C is a capacitor, (RC) is a parallel connection between a resistor and a capacitor and R s , C bat and (RC) 1-4 are serially connected. As shown in the discussion section, the number of (RC)-circuits was chosen as the smallest number that fulfilled the first of the above mentioned criteria.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The model of the overvoltage is obtained from an equivalent circuit, R s C bat (RC) 1 (RC) 2 (RC) 3 (RC) 4 , where R is a resistor and C is a capacitor, (RC) is a parallel connection between a resistor and a capacitor and R s , C bat and (RC) 1-4 are serially connected. As shown in the discussion section, the number of (RC)-circuits was chosen as the smallest number that fulfilled the first of the above mentioned criteria.…”
Section: Resultsmentioning
confidence: 99%
“…A weighing factor of 1/t n was used in the calculation of Err to equalize the weighting of the involved variables as much as possible and thus stabilizing the conversion of the fitting routine: Suppose (RC) 1 primarily models the part of the impedance spectrum from 0.1 Hz to 0.01 Hz and (RC) 4 primarily models the part of the impedance spectrum from 0.001 Hz to 0.0001 Hz. This means the U m (t) measurements from 10 seconds to 100 seconds are primarily modeled by (RC) 1 and the U m (t) measurements from 1000 seconds to 10000 seconds are primarily modeled by (RC) 4 (temporarily disregarding that the we only measured U m (t) for 3600 seconds).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Barsoukov et al recently incorporated this technique into an electrochemical impedance spectrometer by using a variety of excitation signals such as current step, voltage step, current interrupt, and others (31). One vendor's instrument made high-frequency measurements first with the FRA, and then the multiwave FFT method took over when the frequency went below a certain limit.…”
Section: Measuring Impedancementioning
confidence: 99%
“…[10][11][12][13][14][15][16][17] By investigating the impedance response, the charge transport resistance, including electron transport in the solid phase, ionic transport in the electrolyte, solid-state diffusion in the active material, and the intercalation process, can be quantified.…”
mentioning
confidence: 99%