A novel PillCam Crohn’s capsule score (Eliakim score) for quantification of mucosal inflammation in Crohn’s disease

Abstract: Introduction Capsule endoscopy is an important modality for monitoring of Crohn’s disease. Recently, a novel panenteric capsule, PillCam Crohn’s (Medtronic, USA), was approved for use. No quantitative index of inflammation for this method is currently available. This sub-study of a prospective randomized controlled Comprehensive individUalized pRoactive ThErapy of Crohn’s Disease trial (CURE-CD) which aimed to compare the correlation and reliability of the novel PillCam Crohn’s score with the existing small bo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
50
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 48 publications
(52 citation statements)
references
References 26 publications
2
50
0
Order By: Relevance
“…It was compared to LS and a strong correlation (r = 0.8 for reader 1 and r = 0.82 for reader 2, P < 0.001 for both) was found between the scores. The calculation of the cut-off values is LS 135 = 4, LS 350 = 5, LS 790 = 8 102 .…”
Section: Sb and Colon Inflammatory Scoresmentioning
confidence: 99%
“…It was compared to LS and a strong correlation (r = 0.8 for reader 1 and r = 0.82 for reader 2, P < 0.001 for both) was found between the scores. The calculation of the cut-off values is LS 135 = 4, LS 350 = 5, LS 790 = 8 102 .…”
Section: Sb and Colon Inflammatory Scoresmentioning
confidence: 99%
“…Recent efforts to validate a scoring system for PCE are welcome. 29 Finally, clinicians may have chosen a panenteric examination because of a clinical suspicion of small bowel disease, thereby making this a non-representative population; were this the case, however, much of it was previously unidentified as the panenteric study still had a major impact on the diagnosis of L4 disease. Finally, assessment of small and large bowel was variable in terms of both completeness and proximity in time prior to PCE.…”
Section: Completeness Of Examinationsmentioning
confidence: 99%
“… 70 Moreover, thanks to a new integrated reading system, this video capsule permitted the recording and further comparison of patients’ images over time, thus monitoring disease activity and extent under treatment. 71 It is particularly relevant in the pediatric population, where this type of “pan-endoscopy” was shown to effectively monitor mucosal inflammation and successfully guide a treat-to target strategy (twofold increase in the rate of MH and deep remission from baseline to week 54; p < 0.05). 72 …”
Section: What Is Next: Capsule Endoscopy Artificial Intelligence and Molecular Imagingmentioning