2015
DOI: 10.1115/1.4031467
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Suspended Hydrogel Membrane Platform for Cell Culture

Abstract: Current cell-culture is largely performed on synthetic two-dimensional (2D) petri dishes or permeable supports such as Boyden chambers, mostly because of their ease of use and established protocols. It is generally accepted that modern cell biology research requires new physiologically relevant three-dimensional (3D) cell culture platform to mimic in vivo cell responses. To that end, we report the design and development of a suspended hydrogel membrane (ShyM) platform using gelatin methacrylate (GelMA) hydroge… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
6
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
6

Relationship

5
1

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 37 publications
2
6
0
Order By: Relevance
“…1G), a correlation supported in previous work [34,37]. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 13…”
Section: Poly(aniline) Synthesis and Materials Characterizationsupporting
confidence: 73%
“…1G), a correlation supported in previous work [34,37]. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 13…”
Section: Poly(aniline) Synthesis and Materials Characterizationsupporting
confidence: 73%
“…For this work, GelMA was chosen as our model hydrogel to encapsulate cells as it is a collagen derivative which possess RGD groups necessary for cell adhesion, contains readily tunable mechanical properties, and exhibits high structural integrity for experiments lasting over one month [41,42]. Additionally, previous work has shown that GelMA properties such as diffusion, swelling, compressive moduli, and degree of crosslinking are highly consistent between batches, allowing for the reduction of outside variables when conducting experiments [43][44][45].…”
Section: Discussionmentioning
confidence: 99%
“…For all constructs, strain percentage was increased from 0 to 40% with a preloaded force of 0.01 N and displacement of 10 lm. The slope of the stress-strain curve from 0 to 10% strain was used to report the compressive modulus as per previous protocols studying GelMA constructs 32 (n = 3 for each time point).…”
Section: Compression Modulusmentioning
confidence: 99%