2019
DOI: 10.1109/tia.2018.2883372
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Three-Phase Transformerless H-8 Topology With Reduced Leakage Current for Grid-Tied Solar PV Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
48
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 51 publications
(48 citation statements)
references
References 27 publications
0
48
0
Order By: Relevance
“…This variation of the ESI topology in [22] and the ZVR topology in [25] is also zero. Meanwhile, it varies within 33% of DC-link voltage with voltage-clamping topology in [21], H8 topology in [23], and modified H8 topology in [24]. The variation in CMV of SCVD topology in [28] is also 33% of DC-link voltage with DPWM and 16% of DC-link voltage with NSPWM.…”
Section: Comparison With Other Three-phase Inverter Topologiesmentioning
confidence: 99%
See 3 more Smart Citations
“…This variation of the ESI topology in [22] and the ZVR topology in [25] is also zero. Meanwhile, it varies within 33% of DC-link voltage with voltage-clamping topology in [21], H8 topology in [23], and modified H8 topology in [24]. The variation in CMV of SCVD topology in [28] is also 33% of DC-link voltage with DPWM and 16% of DC-link voltage with NSPWM.…”
Section: Comparison With Other Three-phase Inverter Topologiesmentioning
confidence: 99%
“…Compared to the ESI topology in [22], the CCMVI topology uses two less switches and four more diodes as highlighted in Table 3. Compared to H8 topology in [23] and modified H8 topology in [24], the proposed inverter uses three more capacitors, two more switches and four more diodes as shown in Table 3. Compared to the ZVR topology, the proposed inverter uses eight less diodes, one more capacitor and one more switch as highlighted in Table 3.…”
Section: Pwm Control Technique For Proposed Ccmvimentioning
confidence: 99%
See 2 more Smart Citations
“…To increase the stability and reliability of the network, the frequency control of the network and the control of the active and reactive generation capacities have been published and addressed in this standard. So the main problems and concerns in a transformer-less PV inverter can be summarized in the efficiency, [23][24][25][26] cost, [27][28][29][30] and reliability [31][32][33][34] dimensions.…”
Section: Introductionmentioning
confidence: 99%