2020
DOI: 10.3390/electronics9122195
|View full text |Cite
|
Sign up to set email alerts
|

A Novel Zero Dead-Time PWM Method to Improve the Current Distortion of a Three-Level NPC Inverter

Abstract: This paper proposes a novel pulse width modulation (PWM) for a three-level neutral point clamped (NPC) voltage source inverter (VSI). When the conventional PWM method is used in three-level NPC VSI, dead time is required to prevent a short circuit caused by the operation of complementary devices on the upper and lower arms. However, current distortion is increased because of the dead time and it can also cause a voltage unbalance in the dc-link. To solve this problem, we propose a zero dead-time width modulati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 31 publications
0
4
0
Order By: Relevance
“…and yields the control input u (t) among two hysteresis bands: upper hysteresis bands (UU) and lower hysteresis bands (BL) [28][29][30][31]. Such control input u(t) drives the PWM block to give the perfect interface between inverter and grid.…”
Section: Designmentioning
confidence: 99%
See 1 more Smart Citation
“…and yields the control input u (t) among two hysteresis bands: upper hysteresis bands (UU) and lower hysteresis bands (BL) [28][29][30][31]. Such control input u(t) drives the PWM block to give the perfect interface between inverter and grid.…”
Section: Designmentioning
confidence: 99%
“…The authors in [26] dealt with TNP-MLI for PV application with two separate MPPTs for the DC-Link and investigated conduction loss for the inverter. Some similar structure of T type MLI with different PWM scheme is also discussed in [27][28][29][30]. The NPC-MLI majorly suffered by DC-link capacitors balancing.…”
Section: Introductionmentioning
confidence: 99%
“…Voltage and current transductions along with the ADC are also modelled with an equivalent delay and respective digital filters [21]. In short, the considered system model is related to the OSMOSE WP3 demonstrator [9,22], which has been validated during FATs [23].…”
Section: Simulation Model Description and Negative Sequence Impedance Model Validationmentioning
confidence: 99%
“…With the development of inverter technology, the pulse width modulation strategy is being improved and perfected [1][2][3]. Rail traction inverters often exhibit low switching frequencies, limited to a few hundred hertz, due to constraints on power device switching losses [4][5][6].…”
Section: Introductionmentioning
confidence: 99%