2016
DOI: 10.1016/j.nimb.2016.07.002
|View full text |Cite
|
Sign up to set email alerts
|

A performance test of a new high-surface-quality and high-sensitivity CR-39 plastic nuclear track detector – TechnoTrak

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
34
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 41 publications
(35 citation statements)
references
References 37 publications
1
34
0
Order By: Relevance
“…The principle of heavy ion detection has been described elsewhere. 21,24 In brief, a heavy ion passes through the CR-39 detector and causes latent track damage. CR-39 has the ether and two carbonate esters, that are composed of carbonyl (C = O) and C-O-C bonds, in the center.…”
Section: A Cr-39 Plastic Charged Particle Detectorsmentioning
confidence: 99%
“…The principle of heavy ion detection has been described elsewhere. 21,24 In brief, a heavy ion passes through the CR-39 detector and causes latent track damage. CR-39 has the ether and two carbonate esters, that are composed of carbonyl (C = O) and C-O-C bonds, in the center.…”
Section: A Cr-39 Plastic Charged Particle Detectorsmentioning
confidence: 99%
“…This is because the dosimetry is based on LET spectroscopy [14,15], and the autoradiography [12,13] has sub-micron position resolution under optical microscopy. Several co-visualization methods of cells and ion tracks have been developed with CR-39.…”
Section: Introductionmentioning
confidence: 99%
“…The result after etching is a conical pit, referred to as a nuclear track, in the surface of the PNTD. The size of the elliptical interface of the nuclear track and the post-etch surface of the CR-39 layer is proportional to the LET of the charged particle that produced the original latent damage trail 14,15 . Scanning the post etch surface by means of AFM permits the dimensions of the elliptical nuclear tracks to be measured 16 .…”
Section: Methodsmentioning
confidence: 99%
“…Since elliptical track size is proportional to LET, an LET spectrum and integrated values of absorbed dose and dose equivalent can be determined. The measured size of each track is converted to LET by means of an empirically determined detector response function found by measuring tracks of known LET from heavy ion exposures 13,15 . The detector response function was obtained by means of exposure and subsequent readout of CR-39 to beams of known LET particles (i.e.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation