A Personal Cascade Impactor: Design, Evaluation and Calibration

Abstract: A cascade impactor has been developed that is suitable for personal sampling. The impactor can be used with four, six, or eight stages with cut points ranging from 0.5 micron to 21 micron aerodynamic diameter. Although the impactor can be operated over a fairly wide flow rate range, it is designed specifically to be operated at 2 L/min so that a personal sampler may be used as the air mover. The nozzles of the impactor are radial slots with six slots per stage for the first six stages. Circular nozzles arrange… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

1989
1989
2021
2021

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 115 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…To improve reproducibility, simplify sampling, and allow for easy comparison with planned in vitro dissolution rate studies, coating of the impaction substrates was not carried out in the present work except for a comparative measurement (Appendix B). Previous studies using the same type of impactor have concluded that some roll-off can be expected at impaction stages G and H (Rubow et al 1987). Cheng et al used the same type of impactor with coating applied on Stage A only.…”
Section: Uncertaintiesmentioning
confidence: 99%
See 1 more Smart Citation
“…To improve reproducibility, simplify sampling, and allow for easy comparison with planned in vitro dissolution rate studies, coating of the impaction substrates was not carried out in the present work except for a comparative measurement (Appendix B). Previous studies using the same type of impactor have concluded that some roll-off can be expected at impaction stages G and H (Rubow et al 1987). Cheng et al used the same type of impactor with coating applied on Stage A only.…”
Section: Uncertaintiesmentioning
confidence: 99%
“…Impactor stage collection efficiencies were determined by Rubow et al (1987) using monodisperse aerosols. Early impaction stages are associated with lower collection efficiencies; thus, the impact on the overall uncertainty is greater when a large fraction of the activity is collected on early impaction stages.…”
Section: Uncertaintiesmentioning
confidence: 99%
“…Personal cascade impactors are also available to obtain the size distribution of a particulate exposure [20, 21]. Cascade impactors consist of sequential impactors in series with decreasing cutoff sizes.…”
Section: Approaches For Estimating Pm Massmentioning
confidence: 99%
“…Although collection efficiency ‫)ܧ(‬ depends on particle size, it is not easily related to the Stokes number [14]. Thus, the actual collection efficiency curves are usually determined experimentally by measuring responses of monodisperse calibration aerosols [15][16][17][18][19][20][21][22][23][24][25][26]. In this work, the following general expression was used:…”
Section: Mathematical Descriptionmentioning
confidence: 99%